Ratings
Non-inductive load (A)
Rated
Resistive load
Lamp load
voltage
NC
NO
NC
125 VAC
10
3
250 VAC
10
2.5
480 VAC
3
1.5
8 VDC
10
3
14 VDC
10
3
30 VDC
6
3
125 VDC
0.5
0.4
250 VDC
0.25
0.2
NC
30 A max.
Inrush
current
NO
15 A max.
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time
constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
5. The above ratings were tested under the following conditions.
(1) Ambient temperature: +20±2°C
(2) Ambient humidity: 65±5%RH
(3) Operating frequency: 20 operations/min
Characteristics
Degree of protection
IP67
Mechanical
10,000,000 operations min.
Durability
Electrical
500,000 operations min.
Operating speed
0.05 mm/s to 0.5 m/s *1
Mechanical
120 operations/min
Operating
frequency
Electrical
20 operations/min
Rated frequency
50/60 Hz
Insulation resistance
100 MΩ min. (at 500 VDC)
Contact resistance
15 mΩ max. (initial value)
Between terminals of the
1,000 VAC, 50/60 Hz for 1 min
same polarity
Dielectric
strength
Between each terminal and
2,000 VAC, 50/60 Hz for 1 min
non-current-carrying part
Rated insulation voltage (Ui)
1,000 VAC
Pollution degree
3 (IEC947-5-1)
(operating environment)
Protection against electric shock
Class II
PTI (tracking characteristics)
175
Switch category
D (IEC335)
Rated operating current (Ie)
10 A
Rated operating voltage (Ue)
250 VAC
Vibration
Malfunction
10 to 55 Hz, 1.5-mm double amplitude *2
resistance
Destruction
1,000 m/s
Shock
resistance
Malfunction
100 m/s
−10°C to +80°C (with no icing)
Ambient operating temperature
Ambient operating humidity
35% to 95%RH
Weight
Approx. 71 g (in case of panel mount plunger)
*1. Only for models with plungers. (Contact your OMRON representative for
information on other models.)
*2. Less than 1 ms under a free state at the operating limits.
Structure and Nomenclature
Structure
Changing the Terminal Protective Cover
around allows the cable to be pulled out
from either the right or the left.
M4 binding head screws (with toothed
washers) are used as the terminal screws.
http://www.ia.omron.com/
Inductive load (A)
Inductive load
Motor load
NO
NC
NO
NC
NO
1.5
10
5
2.5
1.25
10
3
1.5
0.75
2.5
1.5
0.75
1.5
6
5
2.5
1.5
6
5
2.5
1.5
5
5
2.5
0.4
0.05
0.05
0.05
0.2
0.03
0.03
0.03
2
min.
2
min. *1 *2
Pushbutton
Terminal
Protective
Cover
Common
Normally open
terminal (COM)
terminal (NO)
Approved Standard Ratings
UL/CSA
A300
Carry
Rated voltage
current
120 VAC
10A
240 VAC
EN60947-5-1
CCC (GB14048.5)
Applicable category and ratings
AC-12 10 A/250 VAC
Engineering Data
Electrical Durability
10,000
7,000
5,000
125 VAC cosφ=1
3,000
125 VAC cosφ=0.4
250 VAC cosφ=1
1,000
250 VAC cosφ=0.4
700
500
300
100
70
50
30
Operating temperature: +20
Operating humidity: 65
Operating frequency: 20 operations/min
10
0
2
4
6
Mechanical Durability (D4MC-5000)
10,000
Operating temperature: +20
Operating humidity: 65
No load
5,000
Operating frequency: 120 operations/min
2,000
1,000
500
200
100
0.01 0.02
0.05 0.1
0.2
0.5
Roller
Case
Built-in switch
Seal rubber
Normally closed
terminal (NC)
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
D4MC
Current (A)
Volt-amperes (VA)
Make
Break
Make
60
6
7,200
30
3
±
2°C
±
5%RH
8
10
12
Switching Current (A)
±
2 ° C
±
5%RH
1
2
5 10
OT (mm)
Contact Form
(COM) 1
2 (NC)
4 (NO)
Break
720