Microprocessor Cooling Fan; Removing The Microprocessor Cooling Fan - Dell Precision 530 Service Manual

Dell precision 530: service manual
Hide thumbs Also See for Precision 530:
Table of Contents

Advertisement

Microprocessor Cooling Fan

Removing the microprocessor cooling fan

Replacing the microprocessor cooling fan
Removing the Microprocessor Cooling Fan
CAUTION:
Before you perform this procedure, see
For You and Your
Computer."
NOTICE:
Before disconnecting a device from the computer or removing a
component from the system board, verify that the standby power light on the
system board has turned off. To locate this light, see
Components."
Turn off the computer and devices, disconnect them from their
1
electrical outlets, wait at least 10 to 20 seconds, lay the computer on its
right side, and
open the computer
Remove the microprocessor airflow
2
Disconnect the fan power cable from its connector on the system
3
board. To locate this connector, see
NOTE:
There are two microprocessor cooling fans (FAN_P0 and
FAN_P1).
Gently push the plastic locking tab down, and slide the fan down to
4
disengage the four anchor tabs that hold the fan to the chassis wall.
Pull the fan away from the chassis wall (see the following figure).
"Safety First—
"System Board
cover.
shroud.
"System Board
Components."
113