INSTALLATION & OPERATION Compact Refrigerators Delfield 980 S. Isabella Rd., Mt. Pleasant, MI 48858 (989) 773-7891 or (800) 733-8829 • Fax (989) 773-3210 www.delfield.com MANUAL 4400 Series Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage.
IMPORTANT WARNING AND SAFETY INFORMATION WARNING Read this manual thoroughly before operating, installing, or performing maintenance on the equipment. FAILURE TO FOLLOW INSTRUCTIONS IN THIS MANUAL CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
Serial Number Location The serial number on all 4400 series compact refrigera- tors is printed under the top nosing directly above the door when the door is in the closed position. The serial number on all 4400 series two-door compact refrigerators is printed above the right hand door.
64” 31.5” D4464N four drawer 64” 31.5” 4472N three door 72” 31.5” D4472N six drawer 72” 31.5” WORk TOP REFRIGERATOR bASES WITH 4” bACkSPLASH MODEL DESCRIPTION OVERALL ST4427N one door 27” 31.5” STD4427N two drawer 27” 31.5” ST4432N one door 32”...
MODEL DESCRIPTION OVERALL UC4427N one door 27” 31.5” UCD4427N two drawer 27” 31.5” UC4432N one door 32” 31.5” UCD4432N two drawer 32” 31.5” UC4448N two door 48” 31.5” UCD4448N four drawer 48” 31.5” UC4460N two door 60” 31.5” UCD4460N four drawer 60”...
Page 7
72” 31.5” D4472N-12 six drawer 72” 31.5” 4472N-18 three door 72” 31.5” D4472N-18 six drawer 72” 31.5” SALAD TOP REFRIGERATOR bASES STORAGE SHELVES 1/6 PAN CUBIC FT. SQ. FT. CAPACITY 36” 3.24 36” 1.38 — 36” 10.7 5.48 36”...
Page 8
MEGA TOP REFRIGERATED FRONT bREATHERS MODEL DESCRIPTION OVERALL 4427N-9M one door 27” 31.5” D4427N-9M two drawer 27” 31.5” 4432N-12M one door 32” 31.5” D4432N-12M two drawer 32” 31.5” 4448N-18M two door 48” 31.5” D4448N-18M four drawer 48” 31.5” 4460N-12M two door 60”...
Do not pack refrigerator so full that air cannot circu- late. Outside Cabinet 4400 Series equipment door and drawer models These cabinets have Delfield’s “front-breathing” design. They may be installed flush against a wall or built into a counter as required.
The 15-P plug shown in Figure 2 is used on the various 4400 Series models. Figure 2. 5-15P Connector Refer to the amperage data list in SPECIFICATIONS, the serial tag, your local code or the National Electrical Code to be sure the cabinet is connected to the proper power source.
NSF-7 requirements. The temperature control on a flat top unit is located on the back panel inside the refrigerator and can be adjusted to meet the current conditions. The temperature control on a salad top unit is located in the rear of the unit, 14"...
MAINTENANCE CAUTION The thermostat must be turned to OFF and the cabinet disconnected from the power source whenever per- forming service, maintenance functions or cleaning the refrigerated area. STAINLESS STEEL CARE AND CLEANING To prevent discoloration or rust on stainless steel several important steps need to be taken.
bASIC MAINTENANCE Gasket Maintenance Gaskets require regular cleaning to prevent mold and mildew build up and also to maintain the elasticity of the gasket. Gasket cleaning can be done with the use of warm soapy water. Avoid full strength cleaning products on gaskets as this can cause them to become brittle and prevent proper seals.
Flat Top Units EVAPORATOR FANS TEMPERATURE CONTROL Salad Top Units Temperature Control Knob Access NEMA 5-15P Supply Cord and Plug furnished BLACK WHITE CONDENSING UNIT NEMA 5-15P Supply Cord and Plug furnished TEMPERATURE CONTROL WIRING DIAGRAMS...
Delfield Parts Depot or an authorized Delfield dealer. The defective part invoice must be returned to Delfield within 15 days after the date of service to be eligible for warranty coverage. All claims must include the model, serial number, an original date of installation and customer identification.
(30) days of receipt of the Unit, ninety (90) days from the date of installation Delfield will pay all related labor costs. Delfield will pay the return costs if the Unit or part thereof was defective.