Morsetto
L
N
3
4
5
MARCIA + COND
6
MARCIA + COND
7
8
LAMPEGGIANTE
9
10
11
12
13
PHOT/OPEN U.P.
14
15
Terminal
L
N
3
4
5
6
7
8
9
10
11
12
13
14
15
16 -
LUNA AC B
Definizione
FASE
Alimentazione monofase 220-230Vac, 50/60Hz
NEUTRO
Vedi Fig.A
TERRA
Messa a terra
TERRA
Collegamento motore.
MARCIA + COND Marcia Motore e condensatore
MARCIA + COND Marcia Motore e condensatore
COM Comune Motore
COM
LAMPEGGIANTE 220-230Vac
80W Max.
12 Vac
Uscita alimentazione accessori.
12 Vac
Ingresso di sicurezza BAR/CLOSE U.P.
Con DIP 4=OFF
Ingresso configurabile come costa non verificata N.C. (DIP 5 OFF) o come costa di sicurezza verificata tipo 8k2 (DIP 5 ON)
BAR/CLOSE U.P.
Far riferimento alla FIG.A3 - A4
Con DIP 4=ON
Ingresso configurato come CLOSE U.P. (N.O.)
Ingresso di sicurezza PHOT (N.C.)
Con DIP 4=OFF
In caso di oscuramento, le fotocellule sono attive sia in apertura che in chiusura. Un oscuramento della fotocellula in chiu-
sura, inverte il moto solo dopo il disimpegno della fotocellula. Se non si utilizza lasciare il ponticello inserito.
Far riferimento alla FIG.A2
Con DIP 4=ON
Ingresso configurato come OPEN U.P. (N.O.)
START/OPEN
Ingresso di comando (N.O.) START/OPEN.
Comune
Comune ingressi START, PHOT e BAR
Definition
LINE
Single-phase power supply 220-230Vac, 50/60Hz
See Fig.A
NEUTRAL
EARTH
Grounding
EARTH
Motor connection.
START + CAP
START + CAP Motor Start and capacitor
START + CAP Motor Start and capacitor
START + CAP
COM Motor Common
COM
FLASHING 220-230Vac
FLASHING
110-120Vac
80W Max.
12 Vac
Accessories power supply output.
12 Vac
Safety input
With DIP 4=OFF
Input that can be set up as N.C. non-verified edge (DIP 5 OFF) or as verified safety edge type 8k2 (DIP 5 ON)
BAR/CLOSE U.P.
Refer to
FIG.A3 - A4
With DIP 4=ON
Input configured as CLOSE U.P. (N.O.)
Safety input PHOT (N.C.)
Con DIP 4=OFF
In case of obscuration, the photocells are active both in opening and in closing. An obscuration of the photocell during
PHOT/OPEN U.P.
closing, reverses the motion only after the photocell has been disengaged. If not used leave the jumper inserted.
Refer to FIG.A2
With DIP 4=ON
Input configured as OPEN U.P. (N.O.)
START/OPEN
Command input (N.O.) START E/OPEN.
Comune
Comune ingressi START, PHOT and BAR
ITALIANO
110-120Vac, 50/60Hz
110-120Vac
ENGLISH
110-120Vac, 50/60Hz
BAR/CLOSE U.P.
Descrizione
Description