8 a/d inputs 16-bit (single ended) or 4 a/d inputs16-bit (differential) 8 optocoupler isolated digital inputs 2 optocoupler isolated digital outputs 5 counters 32 bit lcd display (exdul-581e only)
Table of Contents

Advertisement

Reading from the information registers
The EXDUL module provides several
16-byte wide information areas which
hold module information such as
serial number or Hardware identifier.
Additionally, the user can also read out
the writable user registers.
Information: All of the information areas can only be read as a whole
16-byte block.
Example: Read information area UserA (User string = „EXDUL-581")
An 8-byte block is transmitted and a 20-byte block is received with content from UserA or
UserB
Byte
Transmit
0
0C
1
00
2
00
3
01
00 (UserA)
4
01 (UserB)
5
00
6
00
7
01
8
9
10
11
12
13
14
15
16
17
18
19
EXDUL-581E / EXDUL-581S © 2019 by Messcomp Datentechnik GmbH
Representing
Command code 1st Byte
Command code 2nd Byte
Command code 3rd Byte
Length byte → 4Byte
Information byte
reserved
reserved
Read function info area
wasco
Info Area
UserA
UserB
Hardware ID
Serial Number
Receive
Representing
0C
Command code 1st Byte
00
Command code 2nd Byte
00
Command code 3rd Byte
Length byte → 16 Byte
04
45
Data 1st character E
58
Data 2nd character X
44
Data 3rd character D
55
Data 4th character U
4C
Data 5th character L
2D
Data 6th character -
35
Data 7th character 5
38
Data 8th character 8
31
Data 9th character 1
20
Data 10th character [blank]
20
Data 11th character [blank]
20
Data 12th character [blank]
20
Data 13th character [blank]
20
Data 14th character [blank]
20
Data 15th character [blank]
20
Data 16th character [blank]
®
Info Byte
0
1
3
4
asci
asci
asci
asci
asci
asci
asci
asci
asci
asci
asci
asci
asci
asci
asci
asci
EV03