Wasco EXDUL-581E User Manual page 53

8 a/d inputs 16-bit (single ended) or 4 a/d inputs16-bit (differential) 8 optocoupler isolated digital inputs 2 optocoupler isolated digital outputs 5 counters 32 bit lcd display (exdul-581e only)
Table of Contents

Advertisement

11.4.5 Structure of commands
Writing into the info registers
The EXDUL module provides several writable information registers.
UserA/B are two 16-byte areas for the user to store information into a
non-volatile memory (FLASH). The registers are writable only as a whole
16-byte block.
Example: enter the character string EXDUL-581 into register UserA and UserB
Byte
Transmit
0
0C
1
00
2
00
3
05
00 (UserA)
4
01 (UserB)
5
00
6
00
7
00
8
45
9
58
10
44
11
55
12
4C
13
2D
14
35
15
38
16
31
17
20
18
20
19
20
20
20
21
20
22
20
23
20
EXDUL-581E / EXDUL-581S © 2019 by Messcomp Datentechnik GmbH
Info area
UserA
UserB
Receive
0C
00
00
00
wasco
Info Byte
0
1
Representing
Command code 1st Byte
Command code 2nd Byte
Command code 3rd Byte
Lenght prefix byte => 20 Byte
Info byte
reserved
reserved
Info area of write operation
Data 1st character E
asci
Data 2nd character X
asci
Data 3rd character D
asci
Data 4th character U
asci
Data 5th character L
asci
Data 6th character -
asci
Data 7th character 5
asci
Data 8th character 8
asci
Data 9th character 1
asci
Data 10th character [blank]
Data 11th character [blank]
Data 12th character [blank]
Data 13th character [blank]
Data 14th character [blank]
Data 15th character [blank]
Data 16th character [blank]
®
asci
asci
asci
asci
asci
asci
asci
EV03
53

Advertisement

Table of Contents
loading

This manual is also suitable for:

Exdul-581sA-371772371760

Table of Contents