8 a/d inputs 16-bit (single ended) or 4 a/d inputs16-bit (differential) 8 optocoupler isolated digital inputs 2 optocoupler isolated digital outputs 5 counters 32 bit lcd display (exdul-581e only)
Table of Contents

Advertisement

11.4.4 Command overview
Hexcode
0C 00 00
0C 00 03
0C 00 08
0C 00 0C
0C 00 0D
08 00 00
08 00 01
0A 00 00
0A 00 01
0A 00 02
0A 00 06
0A 00 07
0A 00 08
0A 00 09
0A 00 0A
0A 00 0B
09 00 00
09 00 01
09 00 02
09 00 03
09 00 04
EXDUL-581E / EXDUL-581S © 2019 by Messcomp Datentechnik GmbH
Representing
Read and write info register
Read and write LCD register
Read and write network configuration
Read and write security configuration
Change password
Read and write optocoupler outputs
Edit optocoupler inputs
AD Single measurement
AD Single measurement with averaging
AD block measurement with averaging
ADC FIFO Reset
ADC FIFO read out overflow flag
Read out ADC FIFO
AD Multiple measurement
Start AD continuous sampling
Stop AD continuous sampling
Counter0
Counter1
Counter2
Counter3
Counter4