Wasco EXDUL-581E User Manual page 15

8 a/d inputs 16-bit (single ended) or 4 a/d inputs16-bit (differential) 8 optocoupler isolated digital inputs 2 optocoupler isolated digital outputs 5 counters 32 bit lcd display (exdul-581e only)
Table of Contents

Advertisement

wasco
®
Once a stable Ethernet connection is established, you can access the
EXDUL-581 web page via any Internet browser. Upon prompting the host-
name http://EXDUL-581, the browser should open the EXDUL-581 web
page. Click the button TCP/IP Config to open following configuration scr
Once you disabled DHCP, you can enter your desired IP address, subnet
mask, and the desired hostname. By clicking the button Konfiguration
speichern, the currently entered data will be transferred to the internal
memory of the EXDUL-581. From this point on, the module only can be
addressed via the IP address set here, or via the indicated hostname,
respectively. The used PC or LAN must be located in the same network.
Important note: Each device or module in a network must have its unique
IP address or hostname, second assignment is not permitted! The host-
name may be chosen arbitrarily, but may contain only the ASCII digits 0
through 9 and the letters A through Z (leave out upper and lower case)
and - (hyphen-minus).
Some IP addresses are reserved or have special functions such as:
127.0.0.1 (local host).
192.168.1.0 (0 is the network address) with 255.255.255.0 (subnet
mask).
EXDUL-581E / EXDUL-581S © 2019 by Messcomp Datentechnik GmbH
EV03
15