DAVIS Weather Monitor II EZ-Mount Install Manual page 3

Davis weather monitor ii ez-mount weather-accessories: install guide
Table of Contents

Advertisement

G
S
ETTING
TARTED
Follow the steps below to install your station. At various stages of this installa-
tion, you will be advised to test the system to ensure proper functioning.
1. Detach and remove the extension tube from the support tube by cutting the two
black cable ties.
2. Attach the anemometer arm to the support tube as shown below. Make sure that the
anemometer is positioned over the white field case and NOT over the black rain col-
lector cone.
3. Attach the wind cups to the anemometer.
Push the wind cups onto the shaft as far as they will go, then tighten the set
screw. The cups should drop slightly and into the ideal position automati-
cally. Spin the wind cups. If they do not spin freely, loosen the set screw and
lower the cups slightly. Repeat until the wind cups spin freely.
Getting Started
Anemometer Arm
Anemometer
Cable
Support Tube
a. Push cups onto
stainless steel shaft
Anemometer
Lock
#12 x 1-1/2"
Washer
Screw
Hex
Nut
Cable Tie
b. Tighten set screw
with allen wrench
Page 3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Weather wizard iii ez-mountEz-mount