System Traps

Trap
Protection Switching
Protection Switch all data has been routed from the primary card
Card Removed
Card Failure
Communication
Fail
Max Switches
61200659L1-1
(VT Path Remote Failure Indication)
The unit is receiving a VT path remote failure
indication. VT-RFI is declared when the
incoming VT path remote defect indication (VT-
RDI, "1" in bit 4 of the VT-Path Overhead byte
(V5) in five contiguous frames) lasts for 2.5 +/-
0.5 seconds.
(VT Path Signal Label Mismatch)
The controller card is detecting a signal label
mismatch in the VT path. A received signal label
is mismatched if it does not equal the locally
provisioned value or the value "equipped non-
specific".
(VT Path Unequipped)
The controller card detects that the VT path is
unequipped. The VT path is not provisioned.
Byte V5 of the STS path overhead is set to zero.
If enabled, the unit issues a trap when...
to the stand-by card.
a controller card has been removed.
a controller card has failed. This is a critical
alarm only when the back-up card is not
installed or is not working properly.
communication between controller cards A
and B has failed.
the M
S
AX
WITCH
Max. Switch Threshold on page 3-6).
MX2800 STS-1 User Manual
Chapter 3. Configuration
T
is reached (see
HRESHOLD
3-31