5
A
Display RST MASK 03 (Green). / [MKS S53]
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
Set VOL OFFSET to the current setting value minus 48. / [VOF ***]
Determine the current VOL OFFSET setting value as the final value.
[To the Main flowchart (2)]
Recovery flowchart (1-3)...Changing the VOL OFFSET setting voltage
[From the Main flowchart (1) ]
RST MASK 02 (Red)
Gradually decrease the VOL OFFSET value until disappear the
discharge (dead cell).
The VOL OFFSET value must be 107 or greater.
Current VOL OFFSET < 107?
Display RST MASK 03 (Green). / [MKS S53]
[To the Recovery flowchart (1-4)]
5
6
Yes
No
Yes
No
PDP-6010FD
6
7
Replacement of abnormal circuits or
re-replacement of the panel required
Replacement of abnormal circuits or
re-replacement of the panel required
7
8
A
B
C
D
E
F
133
8
Need help?