Connection Technology; Indicators And Operational Controls; Indicators And Operational Controls In The Control Panel - Leuze electronic DDLS 548i Manual

Optical data transmission for 100 mbit/s ethernet - version 200m
Table of Contents

Advertisement

1
1
Device with frequency F3 (DDLS 5XX xxx.3 YY)
2
Device with frequency F4 (DDLS 5XX xxx.4 YY)
3
Frequency F3
4
Frequency F4
Fig. 3.2:
Optical data transmission on two frequencies
The received signal level (SIGNAL QUALITY) is measured on both devices. If the received signal level
drops below a certain value (SIGNAL QUALITY indicator shows only red and orange), the intensity warning
is activated.
The intensity warning is applied on switching output IO1 of the POWER connection.
3.2

Connection technology

A-coded, M12 connection for the supply voltage with integrated switching input and output.
D-coded, M12 connection for the Ethernet connection.
3.3

Indicators and operational controls

3.3.1

Indicators and operational controls in the control panel

Operating mode selector switch and operating mode indicator
• Operating mode selector switch [MODE]
The operating mode selector switch is used to switch between the operating modes of the device (see
chapter 6 "Starting up the device").
• Operating mode LEDs AUT, MAN, ADJ, LAS, LLC
The operating mode LEDs indicate the active operating mode.
Leuze electronic
4
DDLS 548i
Device description
3
2
14

Advertisement

Table of Contents
loading

Table of Contents