Warning/ Er-
ror
Received sig-
nal level in-
tensity (ATT)
Temperature
warning
(TMP/W)
Temperature
error (TMP/E)
Laser pre-
failure mes-
sage (LSR)
Hardware er-
ror
Output data
Transmission
diode
Operating
mode activa-
tion
Operating
mode
Leuze electronic
Address
Data type
1.0
Bit
1.1
Bit
1.2
Bit
1.3
Bit
1.4
Bit
Address
Data type
0.0
Bit
0.1
Bit
0.2
Bit Area
...
0.3
0.4
Bit
0.5
Bit
0.6
Bit
0.7
Bit
Value range
Default
0: No warning
0
1:Warning
0: No warning
0
1:Warning
0: No error
0
1: Error
0: No warning
0
1:Warning
0: No error
0
1: Error
Value range
Default
0 ... 1
0
0 ... 1
0
0 ... 1
0
0
0
0
0
DDLS 548i
Unit
Explanation
---
Warning in event of
critical received signal
level
---
Warning upon exceed-
ing the critical tempera-
ture
---
Error message upon
exceeding the critical
temperature
---
Laser pre-failure mes-
sage
---
Error message in event
of hardware defects
Unit
Explanation
---
Switch transmitter
diode on/off
0 -> 1: Transmitter
diode off
1 -> 0: Transmitter
diode on
---
Toggle bit for accepting
the selected operating
mode (see following
bits)
0 -> 1: Activation
1 -> 0: Activation
---
0: Automatic mode
1: LAS mode; switch
on alignment laser
2: LLC mode; switch
on Link Loss Counter
3: Invalid value, is ig-
nored
---
Free
---
Free
---
Free
---
Free
PROFINET