Technical Data; Preparing The Device For Exploitation; Requirements Concerning The Place Of Installation; Connection And Actuation - Igloo Wojtek 1.0 W User Manual

Table of Contents

Advertisement

Available languages

Available languages

2.3. Technical data

Tabele 1 Technical data
Name of the
Rated volta-
device
ge [V/Hz]
Wojtek 1.0 W
230/50
Wojtek 1.7 W
230/50

3. PREPARING THE DEVICE FOR EXPLOITATION

3.1. Requirements concerning the place of installation

• Verify whether the cross section of feeding conduits is proper for power consumption of the installed device.
• It is forbidden to connect the device by extension rods or dividers.
• The device should be connected to the separate, properly made electric circuit with plug-in socket with protecting pin
(according to PBUE /Regulations concerning Electric Equipment Construction/)
The device may be actuated solely after confirmation of the fire protection efficiency with results of measu-
res performed according to binding regulations!

3.2. Connection and actuation

• Unpack the device and remove the wooden platform from the basis Fig.4 (p.13)
• The device should be placed on an even and on a sufficiently hard base, and then level it with the help of levelling feet.
• Remove the protection foil from the elements of the device
• If the user shall obtain a device partially disassembled to secure it during transportation, perform the following ope-
rations:
1. Place cross-bars under VGN containers
2. Place VGN containers according to Fig.2 (p.11)
4. Mount front glass screen Fig.1/7 (p.11)
• The first cleaning of the device should be provide right after unpacking, and before turning it on. The unit should
be cleaned with water at a temperature not exceeding 40°C with a neutral detergent. For washing and cleaning
the equipment it is prohibited to use products containing chlorine and sodium varieties, which destroy the protecti-
ve layer and components of the device! Any residue of adhesives or silicone on metal elements should be remo-
ved only with extraction naphtha (not applicable to items made of plastic !). Do not use other organic solvents.
When cleaning the unit is prohibited to use water jet. The unit should be cleaned with a wet rag.
After installation of the device at the destination place it should be left to rest for at least 2 hours before
turning it on (for devices with built in compressor) to set the level of refrigerant in order to prevent problems
with starting up the aggregate.
WARNING: Keep out the cooling circuit from damage!
• Place the plug of the connecting cable directly in plug-in socket (it is forbidden to connect the device by means of
extension cords or dividers!)
Power sockets (optional) may be used to power cash register, weight, and similar receivers with
power not exceeding 500W!
• Turn on the main switch Fig.7/3 (p.11), which activates the temperature regulator, and then aggregate of the device
• Set the temperature on thermostat control panel Fig.7/1 (p.11) (service details on p.17 or 18)
• Turn on the lighting switch Fig.7/2 (p.11)
www.igloo.pl
Rated ligh-
Rated
ting power
current [A]
[W]
3,8
30
7,6
58
Electric
energy con-
Cooled sur-
sumption
face [m2]
[kWh/24h]
10,6
0,46
20,9
0,8
User manual WOJTEK
en
Weight of
Usable sur-
the device
face [dm3]
[kg]
104
140
173
200
12

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Wojtek 1.7 w

Table of Contents