Second Edition • First Printing

Work Area Safety

Electrocution Hazards
This machine is not electrically insulated and will
not provide protection from contact with or
proximity to electrical current.
Line Voltage
0 to 50KV
50 to 200KV
200 to 350KV
350 to 500KV
500 to 750KV
750 to 1000KV
Allow for platform movement, electrical line sway
or sag, and beware of strong or gusty winds.
Part No. 1267884
Obey all local and
governmental regulations
regarding required
clearance from electrical
power lines. At a
minimum, the required
clearance contained in the
chart below must be
followed.
Required Clearance
10 ft
3.05 m
15 ft
4.60 m
20 ft
6.10 m
25 ft
7.62 m
35 ft
10.67 m
45 ft
13.72 m
Work Area Safety
Do not operate the machine during lightning or
storms.
Do not use the machine as a ground for welding.
Tip-over Hazards
Occupants, equipment and materials shall not
exceed the maximum platform capacity for the
restricted or unrestricted range of motion.
Maximum platform capacity
Unrestricted range of motion
Maximum occupants
Maximum platform capacity
Restricted range of motion
Maximum occupants
If the restricted range of motion is selected for the
maximum platform capacity, do not move the
platform into the unrestricted range of motion zone.
Do not exceed the selected maximum platform
capacity.
Do not attach a platform rated at 500 lbs / 227 kg
(unrestricted range of motion) or 1000 lbs / 454 kg
(restricted range of motion) to machines with any
other rated load. See the serial label for the
maximum rated load.
S-80X
Operator's Manual
Keep away from the
machine if it contacts
energized power lines.
Personnel on the ground
or in the platform must not
touch or operate the
machine until energized
power lines are shut off.
500 lbs
227 kg
1000 lbs
454 kg
2