Siemens SIMATIC NET 6GK1110-1AA00 Manual
Siemens SIMATIC NET 6GK1110-1AA00 Manual

Siemens SIMATIC NET 6GK1110-1AA00 Manual

Industrial ethernet wireless lan radio link module rlm

Advertisement

Quick Links

6,0$7,& 1(7
,QGXVWULDO (WKHUQHW :LUHOHVV /$1
5DGLR /LQN 0RGXOH 5/0
0DQXDO
IRU *.$$
C79000-G8976-C170-01
Release 11/2001

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET 6GK1110-1AA00

  • Page 1 6,0$7,& 1(7 ,QGXVWULDO (WKHUQHW :LUHOHVV /$1 5DGLR /LQN 0RGXOH 5/0 0DQXDO IRU *.$$ C79000-G8976-C170-01 Release 11/2001...
  • Page 2: C79000-G8976-C170

    Suggestions for improvement registration of a utility or design, are welcome. are reserved. Siemens AG 2001 C79000-G8976-C170-01 Bereich Automatisierungs- und © Siemens AG 2001 Antriebstechnik Subject to technical change. Geschäftsgebiet Industrie- Automatisierungssysteme Postfach 48 48, D-90327 Nürnberg Siemens Aktiengesellschaft...
  • Page 3 &ODVVLILFDWLRQ RI 6DIHW\5HODWHG 1RWLFHV This document contains notices which you should observe to ensure your own personal safety, as well as to protect the product and connected equipment. These notices are highlighted in the manual by a warning triangle and are marked as follows according to the level of danger: 127( Highlights important information on the product, using the product, or part of the documentation that is of particular importance and...
  • Page 4 SIMATIC , SIMATIC NET and SINEC are registered trademarks of Siemens AG. Third parties using for their own purposes any other names in this document which refer to trademarks might infringe upon the rights of the trademark owners. 6DIHW\ ,QVWUXFWLRQV 5HJDUGLQJ \RXU 3URGXFW Before you use the product described here, read the safety instructions below thoroughly.
  • Page 5 Siemens. This product can only function correctly and safely if it is trans- ported, stored, set up, and installed correctly, and operated and maintained as recommended.
  • Page 6 Before putting the product into operation, note the following warning: &DXWLRQ Before installation and startup, read the instructions in the appro- priate documentation. For ordering data of the documentation, please refer to catalogs or contact your local Siemens represen- tative. Industrial Ethernet Wireless LAN Radio Link Module RLM C79000-G8976-C170-01...
  • Page 7 3UHIDFH 3XUSRVH RI WKH 2SHUDWLQJ ,QVWUXFWLRQV These Operating Instructions support you when configuring, commissioning, and troubleshooting networks including the Industrial Ethernet Wireless LAN Radio Link Module RLM. 7KH 3DFNDJH Verify kit contents as described in chapter "2.2 Verify Kit Contents" (page 17).
  • Page 8 *XLGH WR WKH 0DQXDO To help you to find specific information quickly, these operating instructions include the following parts: • At the front of the operating instructions you will find a complete table of contents. • In the Manual "Industrial Ethernet Wireless LAN, Basics" you will find a Glossary in which the most important specialist terms used in the instructions are defined.
  • Page 9 3HUVRQQHO 4XDOLILFDWLRQ 5HTXLUHPHQWV Only qualified personnel should be allowed to install and work on this equipment. Qualified personnel as referred to in the operating instructions or in the warning notes are defined as persons who are familiar with the installation, assembly, startup and operation of this product and who possess the relevant qualifications for their work, e.g.: •...
  • Page 10: Table Of Contents

    &RQWHQWV :HOFRPH Introducing SIMATIC NET Industrial Wireless LAN ......12 About the AccessPoint RLM ............... 13 Finding Information ................15 ,QVWDOO WKH $FFHVV3RLQW 5/0 Overview ..................... 16 Verify Kit Contents ................17 Write Down Product Identification ............18 Fix Mounting Plate and Power Supply ..........19 Mount the Processor Module and fix with angle iron ......
  • Page 11 Best Place for the RLM ............... 30 Remove the Cover Plate ..............31 7URXEOHVKRRWLQJ Connecting the RLM to an OMC............32 Roaming via multiple RLMs on a switched LAN ......... 32 )XUWKHU 6XSSRUW Who to contact..................34 Automation and Drives, Service & Support......... 35 Service &...
  • Page 12 :HOFRPH ,QWURGXFLQJ 6,0$7,& 1(7 ,QGXVWULDO :LUHOHVV /$1 Welcome to the SIMATIC NET Industrial Wireless LAN, the easy way to wireless computing. Building your wireless network has never been easier. This document introduces you to the Access Point “Radio Link Module (RLM)”...
  • Page 13 $ERXW WKH $FFHVV3RLQW 5/0 $ERXW WKH $FFHVV3RLQW 5/0 The Radio Link Module RLM is a wired to wireless bridge that you can use to connect wireless cells to one another or to a wired (Ethernet) Local Area Network (LAN). The RLM can serve mobile wireless stations, roaming between various locations within a network premises.
  • Page 14 $ERXW WKH $FFHVV3RLQW 5/0 With two CP 1515 the unit can transmit at different channels. This allows you to load balance a heavily used access point and increase the scalability of the wireless LAN. To install the RLM, you need at least one PC Card. This card is not included with your kit, but must be ordered as an additional item.
  • Page 15 )LQGLQJ ,QIRUPDWLRQ )LQGLQJ ,QIRUPDWLRQ This document was designed to give you a brief introduction about the RLM, and the most important information to get it up and running. When you install the RLM Manager program, you can display context- " sensitive help with each screen by clicking the ‘...
  • Page 16: Qvwdoo Wkh $Ffhvv3Rlqw

    ,QVWDOO WKH $FFHVV3RLQW 5/0 2YHUYLHZ Before you start, carefully read the “Industrial Ethernet Wireless LAN” manuals which are included in your RLM kit. This manuals contain installation requirements and important information about using this product. Installing the RLM is easy. Follow the steps below to power up your wireless network: Verify Kit Contents.
  • Page 17: Connect The Network Interfaces

    9HULI\ .LW &RQWHQWV  9HULI\ .LW &RQWHQWV Unpack the RLM and verify that all items are present as pictured in Figure )LJXUH  .LW &RQWHQWV Mounting plate to mount the RLM to a wall (see 2.4 Fix Mounting Plate and Power Supply).
  • Page 18 :ULWH 'RZQ 3URGXFW ,GHQWLILFDWLRQ  :ULWH 'RZQ 3URGXFW ,GHQWLILFDWLRQ Before you proceed, write down the following values as printed on the identification label on the top right side of the processor module of your RLM. Serial Number MAC Address Ethernet Interface Wireless Interface )LJXUH  5/0 ,GHQWLILFDWLRQ /DEHO...
  • Page 19: Best Place For The Rlm

    )L[ 0RXQWLQJ 3ODWH DQG 3RZHU 6XSSO\  )L[ 0RXQWLQJ 3ODWH DQG 3RZHU 6XSSO\ You can mount the RLM on a vertical surface like a wall or place the unit on a flat surface such as a table or cabinet. Prior to mounting it to a fixed location, consider performing a site survey to determine optimal and safe placement for your RLM(s).
  • Page 20 )L[ 0RXQWLQJ 3ODWH DQG 3RZHU 6XSSO\ )LJXUH  0RXQWLQJ WKH 3RZHU 6XSSO\ 2. Connect the AC power cord to the power supply unit. 3. Place the power supply unit at the mid section of the mounting plate as pictured in Figure 4 Mounting the Power Supply.
  • Page 21 0RXQW WKH 3URFHVVRU 0RGXOH DQG IL[ ZLWK DQJOH LURQ  0RXQW WKH 3URFHVVRU 0RGXOH DQG IL[ ZLWK DQJOH LURQ 1. Connect the DC power cable to the DC power inlet of the processor module. 2. Slide the four recesses of the processor module over the corresponding tabs on the mounting plate (see Figure 5 Attaching the Processor Module).
  • Page 22 0RXQW WKH 3URFHVVRU 0RGXOH DQG IL[ ZLWK DQJOH LURQ )LJXUH  $WWDFKLQJ WKH 3URFHVVRU 0RGXOH &$87,21 %HIRUH \RX SURFHHG 9HULI\ WKDW DOO IRXU UHFHVVHV DUH ILWWHG FRUUHFWO\ RQWR WKH FRUUHVSRQGLQJ WDEV RI WKH PRXQWLQJ SODWH 8VH WKH DQJOH LURQ WR IL[ WKH SURFHVVRU ,I WKH SURFHVVRU PRGXOH LV QRW SURSHUO\ VHDWHG DQG QRW IL[HG ZLWK WKH DQJOH LURQ LW PD\ GURS FDXVLQJ VHYHUH SHUVRQDO LQMXU\ DQGRU FDXVLQJ VHULRXV GDPDJH WR WKH 5/0 XQLW...
  • Page 23 &RQQHFW WKH 1HWZRUN ,QWHUIDFHV  &RQQHFW WKH 1HWZRUN ,QWHUIDFHV 1. Insert your PC Card(s) into the processor module. One PC Card slot of the RLM is equipped with a plastic Slot Protector Card. The purpose of this card is to protect the unit from dust when it is used with a single PC Card.
  • Page 24 0RXQW WKH &RYHU 3ODWH 0RXQW WKH &RYHU 3ODWH 1. Position the latches at the inside of the cover underneath the rim at the bottom of the processor module (see arrow-1 in Figure 7 Mounting the Cover Plate). )LJXUH  0RXQWLQJ WKH &RYHU 3ODWH 2.
  • Page 25 3RZHU XS \RXU 5/0 WR VWDUW RSHUDWLRQ 3RZHU XS \RXU 5/0 WR VWDUW RSHUDWLRQ To power up the RLM, connect the unit to a grounding type AC wall-outlet (100-240 VAC) using the standard power cord as supplied with the unit. Placement must allow for easily disconnecting the unit from the AC wall- outlet.
  • Page 26 8VLQJ WKH $FFHVV3RLQW 5/0 &RQQHFW 6WDWLRQV WR WKH 5/0 When powering up the RLM for the first time, your RLM is ready for use. The unit will start bridging operation using the parameters as listed in chapter RLM Start-up Configuration (page 44).
  • Page 27 &XVWRPL]H \RXU 5/0  &XVWRPL]H \RXU 5/0 When setting up the Access Points (RLMs) for the first time you will need to verify the TCP/IP settings of the LAN administrator station and Access Point RLM. You need an IP address for your CP1515 in the LAN administrator station and an IP address for the Access Point RLM.
  • Page 28 &XVWRPL]H \RXU 5/0  ,QVWDOO WKH 5/0 0DQDJHU 6RIWZDUH 1. Insert the SIMATIC NET Wireless LAN CD-ROM in the CD-ROM player of your computer. Your operating system will automatically start the CD. 2. Follow the instructions on your screen. 127( If the CD-ROM does not start automatically: Insert the SIMATIC NET Wireless LAN CD-ROM in the CD-ROM player...
  • Page 29 &XVWRPL]H \RXU 5/0 Select a network computer that satisfies the following requirements: • A Pentium II/266 MHz or faster processor. • Free disk space of 4 Mb. • 64 Mb RAM (128 Mb or more recommended). • Microsoft Windows 98 / ME / 2000 / NT 4.0 operating system. •...
  • Page 30 ,QVWDOODWLRQ 5HTXLUHPHQWV  ,QVWDOODWLRQ 5HTXLUHPHQWV Placement of the RLM must satisfy the following installation requirements: • Connect the unit to a grounding type AC wall outlet (100-240 VAC) using the standard power cord as supplied with the unit. • Placement must allow for easily disconnecting the unit from the AC wall- outlet.
  • Page 31: Remove The Cover Plate

    5HPRYH WKH &RYHU 3ODWH  5HPRYH WKH &RYHU 3ODWH Removing the cover plate of the RLM may be required in the following situations: • changing or replacing the PC Card(s), or • getting access to the ‘Reboot’ and/or ‘Forced Reload’ buttons on the processor module.
  • Page 32: 7Urxeohvkrrwlqj

    7URXEOHVKRRWLQJ &RQQHFWLQJ WKH 5/0 WR DQ 20& To connect the RLM 10/100BASE-T Ethernet interface to an SIMATIC NET Optical Media Converter OMC (6GK1100-2AB00 or 6GK1100-2AC00), the RLM Ethernet interface must be configured to 100 Mbit/s. If the RLM is operating in default mode (auto negotiation), a function block will occur when activating the RLM with a connected OMC.
  • Page 33 5RDPLQJ YLD PXOWLSOH 5/0V RQ D VZLWFKHG /$1 be obtained through messages sent from the user to the corded LAN via the new RLM. Until this occurs, messages from the switched LAN are still forwarded to the mobile user along the previous communication path. The mobile user can no longer be contacted via this route, however.
  • Page 34: Xuwkhu 6Xssruw

    :KR WR FRQWDFW If you have technical questions about using the described product and your problem is not dealt with in the documentation or in the integrated help system, please contact your Siemens representative or dealer. You will find the addresses: •...
  • Page 35 $XWRPDWLRQ DQG 'ULYHV 6HUYLFH 6XSSRUW  $XWRPDWLRQ DQG 'ULYHV 6HUYLFH 6XSSRUW Service & Support from A&D is available round the clock worldwide. The languages spoken are German and English. French, Italian, and Spanish are also spoken on the authorization hotline. )LJXUH  6HUYLFH DQG 6XSSRUW Iˆ…r€ir…t...
  • Page 36 Phone:+49 - (0) 180 - 5050 - 222 Phone:+49 - (0) 911 - 895 - 7200 Fax:+49 - (0) 180 - 5050 - 223 Fax:+49 - (0) 911 - 895 - 7201 E-mail:techsupport@ad.siemens.de E-mail:authorization@nbgm.siemens.de $PHULFD (Johnson City) Mo. to Fr. 8:00 to 19:00 (local time, GMT -5)
  • Page 37 PD[LPXP RI WZR KRXUV FKDUJHG Workdays RQO\ ZLWK WKH 6,0$7,& &DUG 0:00 to 24:00 (local time, GMT +1) Phone:+49 - (0) 911 - 895 - 7777 Fax:+49 - (0) 911 - 895 - 7001 E-mail:techsupport@ad.siemens.de Industrial Ethernet Wireless LAN Radio Link Module RLM C79000-G8976-C170-01...
  • Page 38 Sample application programs These are charged to the SIMATIC CARD. Internet address: http://www.siemens.de/automation/service&support You can also formulate a question for the SIMATIC Knowledge Manager that will find the solution in the knowledge database. If you are working in an area without an online connection, part of the free information area is available on the "SIMATIC Customer Support Knowledge...
  • Page 39: Who To Contact

    7UDLQLQJ IRU 6,0$17,& 1(7  7UDLQLQJ IRU 6,0$17,& 1(7 Who to Contact about Training Courses: Siemens AG Trainings-Center für Automatisierungs- und Antriebstechnik A&D PT 49 Kursbüro Östliche Rheinbrückenstraße 50 76181 Karlsruhe Germany Phone: +49 - (0) 721 - 595 - 2917...
  • Page 40 &HUWLILFDWLRQ  &HUWLILFDWLRQ The products of SIMATIC NET are manufactured and marketed using a quality management system complying with DIN ISO 9001 and certified by DQS (certificate registration no. 2613). The DQS certificate is recognized in all IQNet countries (Reg. No. 2613). Industrial Ethernet Wireless LAN Radio Link Module RLM C79000-G8976-C170-01...
  • Page 41: 6Shflilfdwlrqv

    6SHFLILFDWLRQV $ +DUGZDUH 3K\VLFDO VSHFLILFDWLRQV Dimensions 5x18.5x26 cm (hxwxl) Weight 1.75 kg Power cord length 2.5 meter (OHFWULFDO VSHFLILFDWLRQV Voltage 100-240 V AC, (47-63 Hz) Current 0.2 A Power 20 Watt consumption 7HPSHUDWXUH DQG +XPLGLW\ QR FRQGHQVLQJ Operating 0° to 40° C 20 to 80% Storage -40°...
  • Page 42: Software

    6RIWZDUH $ 6RIWZDUH ZSQW[[[ELQ Factory installed operating software for the RLM. This software, that is loaded into the FlashROM of the access point, controls its features and functions. The ‘xxx’ in the file name refer to the version level of the software.
  • Page 43 5HJXODWRU\ ,QIRUPDWLRQ $ 5HJXODWRU\ ,QIRUPDWLRQ Wireless communication is often subject to local radio regulations. Although wireless networking products have been designed for operation in the license-free 2.4 GHz band, local radio regulations may impose a number of limitations to the use of wireless communication equipment. 127( For more regulatory information that may apply in your country refer to the manual “Industrial Ethernet Wireless LAN Basics”...
  • Page 44: 5/0 6WduwXs &Rqiljxudwlrq

    5/0 6WDUWXS &RQILJXUDWLRQ Your AccessPoint RLM comes with the access point operating software factory installed. Together with this software, the access point has also been loaded with a factory-set configuration, that allows for ‘out-of-the box’ operation. 127( The ‘factory-set’ configuration should not be confused with a ‘default’...
  • Page 45 • When you set the Access Point RLM to ‘forced reload mode’ these values should match the settings listed in the “Industrial Ethernet Wireless LAN RLM Manager, CP 1515 Manager” . 127( Consult the “Industrial Ethernet Wireless LAN RLM Manager, CP 1515 Manager”...
  • Page 46 Industrial Ethernet Wireless LAN Radio Link Module RLM C79000-G8976-C170-01...

Table of Contents