12.2 Indoor Unit

12.2.1
How to Fix Installation Plate
The mounting wall shall be strong and solid enough to prevent it from vibration.
Measuring Tape
MZ16***
The center of installation plate should be at more than 1 at right and left of the wall.
The distance from installation plate edge to ceiling should more than 2.
From installation plate center to unit's left side is 3.
From installation plate center to unit's right side is 4.
: For left side piping, piping connection for liquid should be about 5 from this line.
B
: For left side piping, piping connection for gas should be about 6 from this line.
1
Mount the installation plate on the wall with 5 screws or more (at least 5 screws).
(If mounting the unit on the concrete wall, consider using anchor bolts.)
Always mount the installation plate horizontally by aligning the marking-off line with the thread and using
o
a level gauge.
2
Drill the piping plate hole with ø70 mm hole-core drill.
Line according to the left and right side of the installation plate.
o
The meeting point of the extended line is the center of the hole.
Another method is by putting measuring tape at position as shown in the diagram above.
The hole center is obtained by measuring the distance namely 128 mm for left and right hole respectively.
Drill the piping hole at either the right or the left and the hole should be slightly slanting to the outdoor
o
side.
12.2.2
To Drill a Hole in the Wall and Install a Sleeve of Piping
1
Insert the piping sleeve to the hole.
2
Fix the bushing to the sleeve.
3
Cut the sleeve until it extrudes about 15 mm
from the wall.
When the wall is hollow, please be sure to use
the sleeve for tube assembly to prevent dangers
caused by mice biting the connection cable.
4
Finish by sealing the sleeve with putty or
caulking compound at the final stage.
Wall
More than 1
266 mm
PIPE
HOLE
CENTER
128mm TO
PIPE HOLE
CENTER
128 mm
Model
515 mm
CAUTION
Ceiling
2 screw
More
than 2
3
Installation
plate 1
B
6
5
For best strength of
C
INDOOR unit installation,
it is highly recommended
to locate " " at 5 position
as shown.
Dimension
1
2
3
85 mm
460 mm
Indoor
Sleeve for tube
assembly
ø70 mm
through hole
28
Wall
More than 1
Indoor unit
4
266 mm
PIPE
HOLE
CENTER
A
128mm TO
PIPE HOLE
CENTER
128 mm
4
5
6
460 mm
43 mm
95 mm
Wall
Outdoor
15 mm
Approx. 5 - 7 mm
Putty or caulking compound
Bushing for
tube assembly