Download Print this page
Intel RMS25CB080 Quick Start User Manual

Intel RMS25CB080 Quick Start User Manual

Integrated raid module
Hide thumbs Also See for RMS25CB080:

Advertisement

Quick Links

Intel® Integrated RAID Module
RMS25CB080, RMS25CB040, RMT3CB080,
and RMS25CB080N
Quick Start User's Guide
This guide contains step-by-step instructions for installing
the Intel® Integrated RAID Module RMS25CB080, RMS25CB040,
RMT3CB080, and RMS25CB080N and information on using the
BIOS setup utility to configure a single logical drive array and
install the driver into the operating system.
For more advanced RAID configurations, or to install with other
operating systems, please refer to the Hardware User's Guide.
These guides and other supporting documents
(including a list of supported server boards) are also located on the web at:
http://www.intel.com.
If you are not familiar with ESD (Electrostatic Discharge) procedures used
during system integration, see your Hardware Guide for complete ESD
procedures. For more details on Intel ® RAID controllers, see:
www.intel.com/go/serverbuilder.
Read all cautions and warnings first before starting your RAID Controller
integration.
What you will need to begin
Warning
Read all caution and safety
SAS 2.0 or SATA III hard disk drives (backward compatible to support
statements in this document
SAS 1.0 or SATA II hard disk drives) for Intel
before performing any of the
RMS25CB040, and RMS25CB080N
®
instructions. Also see the Intel
SATA III hard disk drives (backward compatible to support SATA II hard disk drives)
Server Board and Server Chassis
for Intel
®
Integrated RAID Module RMT3CB080
Safety Information document at:
Intel
®
Integrated RAID Module RMS25CB080, RMS25CB040, RMT3CB080, or
http://www.intel.com/support/
RMS25CB080N (SAS/SATA cables need to be prepared separately)
motherboards/server/sb/cs-010770.
SAS/SATA cable accessory kit, which can be ordered from Intel separately.
htm
for complete safety information.
Please see the Tested Operating System List for available cable accessory kits at:
http://www.intel.com/p/en_US/support/server
Warning
Intel
®
Server Board with SAS Module connector
Resource CD, which is shipped with systems or boards
Installation and service of
Operating system installation media: Microsoft Windows Server 2003*,
this product should only be
Microsoft Windows Server 2008*, Microsoft Windows Server 2012*,
performed by qualified service
Microsoft Windows 7*, Microsoft Windows Vista*,Red Hat* Enterprise Linux,
personnel to avoid risk of injury from
SUSE* Linux Enterprise Server, VMware* ESX Server 4, and VMware* ESXi 5.
electrical shock or energy hazard.
1
Caution
Installing the Barrel Standoff
Observe normal ESD
[Electrostatic Discharge]
procedures during system
A
Power down the system and disconnect the power cord.
integration to avoid possible
damage to server board and/or
B
Locate the matching SAS Module connector on your server board,
other components.
see your server board documentation.
C
Insert the barrel standoffs into the matching holes in the server board.
Tools Required
The Intel
Server Board S2600IP is shown for illustrative purpose.
®
Phillips*
Anti-static
screwdriver
wrist strap
Intel is a registered trademark of Intel Corporation or its
subsidiaries in the United States and other countries.
*Other names and brands may be claimed as the property
of others. Copyright © 2014, Intel Corporation. All rights
reserved.
G42740-006
Intel® Integrated RAID Module RMS25CB080 as shown
*
2
Install the RAID Module
A
Power down the system and disconnect the power cord.
®
Integrated RAID Module RMS25CB080,
B
Remove the system cover.
C
Attach the RAID Module to the matching server board connector and
press the module card firmly to engage the barrel standoffs.
The Intel
®
Integrated RAID Module RMS25CB080 is shown for
illustrative purpose.
D
Press down gently but firmly to ensure that the card is properly seated in
the connectors, and then insert the four pin standoffs into the barrel
standoffs respectively.
Building Value with Intel®
Server Products, Programs, and Support
Get the high-value server solutions you
need by taking advantage of the outstanding
value Intel
provides to system integrators:
®
High-quality server building blocks
Extensive breadth of server building blocks
Solutions and tools to enable e-Business
Worldwide 24x7 technical support
(AT&T Country Code + 866-655-6565)
World-class service, including a
three-year limited warranty and Advanced
Warranty Replacement
1
For more information on Intel
's added-value
®
server offerings, visit the Intel
ServerBuilder
®
website at:
www.intel.com/go/serverbuilder.
Choosing the Right RAID Level
RAID
D1
0
D3
D4
D5
D7
D1
1
D2
D4
D3
D4
D1
5
D3
D4
P
D7
D1
6
D4
D3
P1
P2
R1
D1
10
D3
D4
D5
D7
D1
50
D5
D4
P
D13
P1
D4
P2
D9
D13
60
P1
D4
P2
D11
D15
3
Connect the RAID Module
A
Connect the wide end of the provided cable to the top silver
connector (ports 0-3).
The Intel
®
Integrated RAID Module RMS25CB080 is shown for
illustrative purpose.
B
Push the cable into the silver connector until it makes a slight click.
C
If using more than four drives, connect the wide end of the second
cable to the bottom silver connector (ports 4-7).
D
Connect the other ends of the cables to SATA drives or to the ports
on a SATA or SAS backplane.
Notes: Both non-expander backplanes (one cable per drive) and
expander backplanes (one or two total cables) are supported.
Drive power cables (not shown) are required.
Ports 4-7
(This connector is not available on
Intel
®
Integrated RAID Module RMS25CB040 )
Intel
®
ServerBuilder is your one-stop
shop for information about all of Intel
®
's
Server Building Blocks such as:
Product information, including
product briefs and technical product
specifications
Sales tools, such as videos and
1
presentations
Training information, such as the
Intel
Online Learning Center
®
Support Information and much more
Rear view of four SATA drives or backplane connected to ports
on the Intel
®
Integrated RAID Module RMS25CB080.
1
Available only to Intel
®
Channel Program
Members, part of Intel
e-Business Network.
®
Go to Step 4 on Side 2
Minimum
Physical
Fail PDs
Drives
Allowed
Method
D2
2
NONE
Striping (speed)
D4
D4
D6
D8
D1
2
1
Mirroring
D2
D4
D3
(redundancy)
D4
D2
P
3
1
Striping and
D4
P
D4
D4
D5
D6
distributed parity
D8
P
(fault tolerance)
D2
P1
P2
3
2
Striping with dual
D4
P1
P2
D4
D4
D4
P2
D5
D6
distributed parity
D7
D8
P1
R0
R1
4
1 per
Striping across
D1
D2
D2
mirrors
mirror set
D3
D4
D4
D4
D4
D4
D5
D6
D6
D7
D8
D8
R0
R5
R5
6
1 per R5
Striping across R5
arrays
D2
P
D3
D4
P
set
D4
P
D6
D4
D7
D4
D4
P
D4
D8
D5
D10
P
D11
D12
D14
P
D15
D16
P
D1
D2
P2
D4
P1
D5
D4
D6
D4
R6
P2
P1
D10
D14
P2
P1
6
2 per R6
Striping across R6
R0
set
arrays
D3
D4
P2
D4
P1
D7
D4
D4
D8
R6
P2
P1
D12
D16
P2
P1
Audible Alarm Information
For information about the audible alarm and how to silence or disable it, see the reverse side of this document.
Intel® Integrated RAID Module
RMS25CB080, RMS25CB040, RMT3CB080,
and RMS25CB080N Reference Diagram
Front View
Module Mounting
Holes
C
B
A
J4B2
Advanced Software
D
Hardware Key Connector
J4B1
Ports 4-7
(This connector is
not available on
®
Intel
Integrated RAID Module
RMS25CB040)
D
For more information on the jumpers referenced in this diagram, refer to the user guide located on the web at:
http://www.intel.com/p/en_US/support/server/
Read
Write
Capacity
Speed
Speed
Good Usage
100%
Excellent Excellent
High throughput
workstation
50%
Very
Good
OS, apps
entry level
good
n-1
Very
Good
Data, web/media
(67-94%)
server
good
n-2
Good
Good
High fault
(50-88%)
tolerance
Database, file,
50%
Very
Good
mail servers
good
n-2
Excellent
Very
Database, file,
(67-94%)
mail servers
Good
n-4
Very
Good
Critical data
(50-88%)
good
J3A1
BBU/RMFBU
Connector
(This connector is
Back View
not available on
®
Intel
Integrated
RAID Module
RMS25CB080N)
Speaker
J4A1
Ports 0-3
SAS Module
Connector

Advertisement

loading

Summary of Contents for Intel RMS25CB080

  • Page 1 RMS25CB080N Reference Diagram cable to the bottom silver connector (ports 4-7). • SAS/SATA cable accessory kit, which can be ordered from Intel separately. Press down gently but firmly to ensure that the card is properly seated in for complete safety information.
  • Page 2 To start Intel RAID Web Console 2 from within the OS: Choose Start | Programs | RAID WebConsole | RAID WebConsole 2. For additional details, see the Intel RAID Software User’s Guide.

This manual is also suitable for:

Rms25cb040Rmt3cb080Rms25cb080n