Built-in Models
note! refer to illustrations in section: 'Control Assembly (Built-in Models)'.
1.
isolate the hot and cold water supplies and operate the control lever to drain
any residual water.
2.
Unscrew the control lever handle, loosen the Grubscrew and pull off the
control lever and Bearing.
3.
carefully unclip the concealing Plate from the Backplate.
note! Use a screwdriver in the cutout to assist separation.
4.
Unscrew the two shroud screws and remove the Backplate from the Mixer.
5.
Unscrew the Filter caps with the
'o Key' (supplied) or a 12 mm
hexagonal wrench and remove the
Filters.
note! Use pliers to carefully remove
the filters.
6.
clean each of the filters under a
jet of water to remove any lodged
particles.
7.
Refit the Filters and tighten the Filter
caps.
note! Make sure that the seal is fitted
correctly and not damaged.
8.
turn on the hot and cold water supplies and check for leaks.
9.
refer to section: 'Control Assembly (Built-in Models)' and follow instructions
4 to 9.