Converting to another gas type
Conversion from one type of gas
to another, should only be under-
taken by an approved and registered
gas installer in strict accordance with
current local and national safety and
building regulations.
Disconnect the hob from the electri-
city supply and turn off the gas sup-
ply.
When converting to another type of
gas, both the main and small jets
need to be changed.
Jet table
The jet markings refer to a ¹/₁₀₀ mm
bore diameter.
Natural gas H
Small burner
Medium burner
Large burner
Wok burner
Liquid gas
Small burner
Medium burner
Large burner
Wok burner
50
Main jet
Small jet
0.76
0.39
0.94
0.42
1.20
0.54
2x 1.07 / 0.72
0.42
0.52
0.23
0.66
0.36
0.81
0.42
2x 0.70 / 0.46
0.25
Changing the jets
Disconnect the hob from the electri-
city supply and turn off the gas sup-
ply.
Changing the main jets
Small, medium and large burners
Remove the pan support, burner
cap and burner head .
Using an M7 socket spanner, un-
screw the main jet
Fit the correct jets securely (see jet
table).
Secure the jets against inadvertent
loosening with sealing wax.