Emergency drain

If the appliance cannot drain the water, carry
out the same procedure, described in 'Cleaning
the drain filter' paragraph. If necessary, clean the
pump.

Frost precautions

If the appliance is installed in an area where the
temperature can reach values around 0° C or
drop below, remove the remaining water from
the inlet hose and the drain pump.
1. Disconnect the mains plug from the mains
socket.
2. Close the water tap.
3. Put the two ends of the inlet hose in a
container and let the water flow out of the
hose.
4. Empty the drain pump. Refer to the emergency
drain procedure.
5. When the drain pump is empty, install the inlet
hose again.
Warning! Make sure that the
temperature is higher than 0
°C before you use the
appliance again.
The manufacturer is not
responsible for damages
caused by low temperatures.
Washing Machine User Manual