Overview
• Power supply modules (two—One for operations and one for redundancy [1+1]) with the following
choices:
• 750-W AC power supply with port-side exhaust airflow (blue coloring) (NXA-PAC-750W-PE)
• 750-W AC power supply with port-side intake airflow (burgundy coloring) (NXA-PAC-750W-PI)
• 1100-W AC power supply with port-side intake airflow (burgundy coloring) (NXA-PAC-1100W-PI2)
• 1100-W AC power supply with port-side exhaust airflow (blue coloring) (NXA-PAC-1100W-PE2)
• 1100-W DC power supply with port-side intake airflow (burgundy coloring) (NXA-PDC-1100W-P1)
• 1100-W DC power supply with port-side exhaust airflow (blue coloring) (NXA-PDC-1100W-PE)
• 1100-W HVAC/HVDC power supply with port-side intake airflow (burgundy coloring)
• 1100-W HVAC/HVDC power supply with port-side exhaust airflow (blue coloring)
Note
The 750-W AC PSU is compatible only with software versions ACI-N9KDK9-14.2 or NXOS-9.3.3 and
onwards.
Note
In the event that only one power supply is operating in an active system and a second power supply is inserted,
the system fan will slow down to 50% of Max speed for 12 seconds. It can take up to 10 seconds for the
second power supply to become active. Please do not remove the first power supply during this time-frame,
in order to avoid system shutdown.
Deployment Scheme for SFP-10G-T-X Transceivers
The following figure shows the maximum configuration density of SFP-10G-T-X SFP+ transceivers for this
switch.
Cisco Nexus 93240YC-FX2 NX-OS Mode Switch Hardware Installation Guide
2
Note
To enable or disable displaying the serial number of the
NXA-SFAN-35CFM-PI or NXA-SFAN-35CFM-PE fan, enter
the [no] hardware fan-sprom command.
(NXA-PHV-1100W-PI)
(NXA-PHV-1100W-PE)
Overview