Summary of Contents for Cisco Nexus 9372PX

  • Page 1 Cisco Nexus 9372PX Switch Configuration Guide for Dell PS Series SANs Dell EMC Engineering June 2017 A Dell EMC Deployment and Configuration Guide...
  • Page 2: Revisions

    Dell believes the information in this document is accurate as of its publication date. The information is subject to change without notice. Cisco Nexus 9372PX Switch Configuration Guide for Dell PS Series SANs | SCG3665...
  • Page 3: Table Of Contents

    2.11 Enable switch ports ............................10 2.12 Save configuration ............................10 2.13 Configure additional switch ..........................10 Technical support and resources ..........................11 Related resources ............................11 Cisco Nexus 9372PX Switch Configuration Guide for Dell PS Series SANs | SCG3665...
  • Page 4: Introduction

    Note: For proper functionality, the switch must be at the firmware version shown in Table 2 before proceeding with this configuration. Using previous firmware versions may have unpredictable results. Note: The latest firmware updates and documentation can be found at: www.cisco.com. This site requires a login credential.
  • Page 5: Cabling Diagram

    Cabling diagram The cabling diagram shown in Figure 1 represents the method recommended by Dell EMC for deploying servers and PS Series arrays. Cabling diagram Cisco Nexus 9372PX Switch Configuration Guide for Dell PS Series SANs | SCG3665...
  • Page 6: Dell Emc Recommended Switch Configuration

    Do you wish to proceed anyway ? (y/n) [n]y switch#reload This command will reboot the system Do you want to continue? (y/n) [n]y Note: The switch will reboot. Cisco Nexus 9372PX Switch Configuration Guide for Dell PS Series SANs | SCG3665...
  • Page 7: Run The Basic System Configuration

    Enable the ssh service? (yes/no) [y]:n Configure the ntp server? (yes/no) [n]:n Configure default interface layer (L3/L2) [L2]:L2 Configure default switchport interface state (shut/noshut) [noshut]:shut Configure CoPP system profile (strict/moderate/lenient/dense) [strict]: Cisco Nexus 9372PX Switch Configuration Guide for Dell PS Series SANs | SCG3665...
  • Page 8: Enable Lldp

    Configure the vPC domain switch(config)#feature lacp switch(config)#feature vpc switch(config)#vpc domain 1 switch(config-vpc-domain)#peer-keepalive destination peer IP address --------:: Management VRF will be used as the default VRF ::-------- switch(config-vpc-domain)#exit Cisco Nexus 9372PX Switch Configuration Guide for Dell PS Series SANs | SCG3665...
  • Page 9: Configure The Port-Channel

    Note: Optionally, to reduce egress port packet drops, use the following command to enable the ultra-burst feature mode: switch(config)# hardware qos ns-buffer-profile ultra-burst Cisco Nexus 9372PX Switch Configuration Guide for Dell PS Series SANs | SCG3665...
  • Page 10: Configure Portfast On Edge Ports

    2.12 Save configuration switch# copy running-config startup-config switch# reload 2.13 Configure additional switch Repeat the steps in sections 2.1 through 2.12 to configure the second switch. Cisco Nexus 9372PX Switch Configuration Guide for Dell PS Series SANs | SCG3665...
  • Page 11: Technical Support And Resources

    Dell TechCenter provide expertise that helps to ensure customer success on Dell EMC Storage platforms. Related resources Referenced or recommended Dell EMC publications:  Dell PS Series Configuration Guide  Dell EMC Storage Compatibility Matrix Cisco Nexus 9372PX Switch Configuration Guide for Dell PS Series SANs | SCG3665...

Table of Contents