Cisco Nexus 93600CD-GX Hardware Installation Manual
Cisco Nexus 93600CD-GX Hardware Installation Manual

Cisco Nexus 93600CD-GX Hardware Installation Manual

Aci-mode switch
Hide thumbs Also See for Nexus 93600CD-GX:
Table of Contents

Advertisement

Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation
Guide
First Published: 2019-09-27
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883

Advertisement

Table of Contents
loading

Summary of Contents for Cisco Nexus 93600CD-GX

  • Page 1 Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide First Published: 2019-09-27 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883...
  • Page 2 Any use of actual IP addresses or phone numbers in illustrative content is unintentional and coincidental. Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this URL: www.cisco.com trademarks.
  • Page 3: Table Of Contents

    Planning for Power Requirements Airflow Requirements Rack and Cabinet Requirements Clearance Requirements C H A P T E R 3 Installing the Chassis Safety Installation Options with Rack-Mount Kits, Racks, and Cabinets Airflow Considerations Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 4 Wiring a 48 V DC Electrical Connector Block A P P E N D I X A Rack Specifications Overview of Racks General Requirements for Cabinets and Racks Requirements Specific to Standard Open Racks Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 5 A P P E N D I X C LEDs Switch Chassis LEDs Fan Module LEDs Power Supply LEDs A P P E N D I X D Additional Kits Rack Mount Kit NXK-ACC-KIT-1RU Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 6 Contents Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 7: Preface

    Braces and a vertical bar within square brackets indicate a required choice within an optional element. Indicates a variable for which you supply values, in context where italics variable cannot be used. Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 8: Documentation Feedback

    What's New in Cisco Product Documentation, at: https://www.cisco.com/warp/public/687/Directory/DirTAC.shtml. Subscribe to What's New in Cisco Product Documentation, which lists all new and revised Cisco technical documentation as an RSS feed and delivers content directly to your desktop using a reader application. The RSS feeds are a free service.
  • Page 9: Overview

    • Overview, on page 1 Overview The Cisco Nexus 93600CD-GX switch (N9K-C93600CD-GX) is a 1-rack unit (RU), fixed-port switch designed for spine-leaf-APIC deployment in data centers. This switch has the following ports: • 28 10/40/100-Gigabit QSFP28 ports (ports 1-28) • 8 10/40/100/400-Gigabit QSFP-DD ports (ports 29-36) •...
  • Page 10 • 1100-W port-side exhaust DC power supply with blue coloring (NXA-PDC-1100W-PE) • 1100-W port-side intake DC power supply with burgundy coloring (NXA-PDC-1100W-PI) Note All fan modules and power supplies must use the same airflow direction. Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 11 The following figure shows the switch features on the power supply side of the chassis. Power supply modules (1 Management port or 2) (AC power supplies (1—RJ-45 copper port) shown) with slots numbered 1 (left) and 2 (right) Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 12 Note All fan and power supply modules must have the same direction of airflow. Otherwise, the switch can overheat and shut down. Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 13 If the switch has port-side exhaust airflow (blue coloring for fan modules), you must locate the ports in the hot aisle. If you locate the air intake in a hot aisle, the switch can overheat and shut down. Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 14 Overview Overview Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 15: Preparing The Site

    Altitude Requirements Altitude rating is based on power supply installed; see critical components list in the system CB report for altitude rating. Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 16: Dust And Particulate Requirements

    The wiring is unlikely to emit radio interference if you use a twisted-pair cable with a good distribution of grounding conductors. If you exceed the recommended distances, use a high-quality twisted-pair cable with one ground conductor for each data signal when applicable. Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 17: Shock And Vibration Requirements

    For n+1 redundancy, you can use one or two power sources for the two power supplies. For n+n redundancy, you must use two power sources and connect each power supply to a separate power source. Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 18 IEC 60950 based safety standards. Note We recommend 8-AWG wire for DC installations in the U.S. Note For the power cables to use with the power supplies, see Power Cable Specifications, on page Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 19: Airflow Requirements

    (for proper mounting of the bottom-support brackets or other mounting hardware). Also, you must have power receptacles that are located within reach of the power cords that are used with the switch. Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 20: Clearance Requirements

    Width of the front clearance area (equal to the width of the chassis with two rack-mount brackets that are attached to it). Note Both the front and rear of the chassis must be open to both aisles for airflow. Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 21: Installing The Chassis

    Starting the Switch, on page 21 Safety Before you install, operate, or service the switch, see the Regulatory, Compliance, and Safety Information for the Cisco Nexus 3000 and 9000 Series for important Safety Information. Warning Statement 1071 Warning Definition IMPORTANT SAFETY INSTRUCTIONS This warning symbol means danger.
  • Page 22: Installation Options With Rack-Mount Kits, Racks, And Cabinets

    You can install the switch using the following rack-mount options: • Rack-mount kit (NXK-ACC-KIT-1RU) which you can order from Cisco. This option offers you easy installation, greater stability, increased weight capacity, added accessibility, and improved removability with front and rear removal.
  • Page 23: Unpacking And Inspecting The Switch

    Unpacking and Inspecting the Switch Before you install the switch, be sure to unpack and inspect the switch for damage or missing components. If anything is missing or damaged, contact your customer service representative immediately. Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 24: Installing The Switch Using The Nxk-Acc-Kit-1Ru Rack-Mount Kit

    • You have inspected the switch shipment to ensure that you have everything ordered. • Make sure that the switch rack-mount kit includes the following parts: • Front rack-mount brackets (2) • Rear rack-mount brackets (2) • Slider rails (2) Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 25 Note Depending on the chassis depth, the back rack-mount bracket may not fit. In that case the back rack-mount bracket is not needed. Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 26 Holding the switch with both hands, position the two rear rack-mount brackets on the switch between the rack or cabinet posts that do not have slider rails attached to them (see the following figure). Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 27 Tighten the 10-32 screws to 20 in-lb (2.26 N·m) or tighten the 12-24 screws to 30 in-lb (3.39 N·m). Step 5 If you attached a grounding wire to the chassis grounding pad, connect the other end of the wire to the facility ground. Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 28: Grounding The Chassis

    Verify that the ground wire is securely attached to the grounding lug by attempting to pull the wire out of the crimped lug. Chassis grounding pad 2 M4 screws are used to secure the grounding lug to the chassis Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 29: Starting The Switch

    Make sure that the connector clicks when fully pushed into the receptacle. b) Connect the other end of the power cable to a power source. Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 30 A setup utility automatically launches the first time that you access the switch and guides you through the basic configuration. For instructions on how to configure the switch and check module connectivity, see the appropriate Cisco Nexus 9000 Series configuration guide.
  • Page 31: Connecting The Switch To The Aci Fabric

    Note To prevent sub-optimal forwarding between endpoints, connect every leaf switch in the fabric to every spine switch in the same fabric. Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 32: Preparing To Connect To Other Devices

    Cisco equipment. In situations where long parallel cable runs cannot be separated by at least 3.3 feet (1 meter), we recommend that you shield any potential noise sources by housing them in a grounded metallic conduit.
  • Page 33: Connecting Leaf Switches To Apics

    Connecting Leaf Switches to APICs You must downlink one or two (recommended for redundancy) Cisco Nexus 9300 platform ACI-mode leaf switches to each Application Policy Infrastructure Controller (APIC) in your ACI fabric. The type of virtual interface card (VIC) installed on the APIC determines the types of interface cables that you can use to connect the leaf switches to the APICs.
  • Page 34: Connecting Leaf Switches To Spine Switches

    Connect the other end of the interface cable to a downlink port on a leaf switch. • For a Cisco 10GBASE-LR or -SR transceiver and cable, insert the transceiver into a downlink optical port on a leaf switch before connecting the cable to the transceiver.
  • Page 35 • If there are modular switches in the fabric, their ACI-mode line cards must already be installed. The line cards can be of the following types: • 36-port 40-Gigabit (such as: N9K-X9736PQ) • 32-port 100-Gigabit (such as: N9K-X9732C-EX) (supported by Cisco Nexus 9504 and 9508 modular switches) • 36-port 100-Gigabit (such as: N9K-X9736C-FX) Note You cannot include NX-OS line cards in the same chassis when running in ACI mode.
  • Page 36: Installing A Gigabit Ethernet Module (Gem)

    First-generation Cisco Nexus 9000 Series switches include those switches that do not contain an EX or an FX in the PID (product identification). Second-generation Cisco Nexus 9000 Series switches include those switches that have an EX or an FX in the PID.
  • Page 37: Setting Up An Optional Console Interface

    Before you begin The console device must support VT100 terminal emulations and asynchronous transmissions. Step 1 Configure the terminal emulator program to match each of the following default port characteristics: • 9600 baud Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 38: Setting Up An Optional Management Connection

    DB-9 connector on the other end of the cable to the serial port on the console device. What to do next You can now perform the initial configuration for the switch (see the Cisco ACI Getting Started Guide). Setting Up an Optional Management Connection You can optionally set up an out-of-band management connection for monitoring and troubleshooting purposes.
  • Page 39: Maintaining Transceivers And Optical Cables

    Transceivers and fiber-optic cables must be kept clean and dust free to maintain high signal accuracy and prevent damage to the connectors. Contamination increases attenuation (loss of light) and should be below 0.35 dB. Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 40 • Inspect routinely for dust and damage. If you suspect damage, clean and then inspect fiber ends under a microscope to determine if damage has occurred. Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 41: Replacing Components

    Hold the module by its handle and do not touch the electrical connectors on its backside. Also, to protect the electrical connectors, avoid letting them come in contact with anything other than the electrical connectors inside the chassis. Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 42: Replacing A Power Supply Module

    If the STS LED does not turn on, slide the module out of the chassis, and visually check the electrical connectors on the back side of the chassis for damage. If damaged, contact Cisco Technical Assistance for help. If undamaged, repeat the previous step to reinstall the module.
  • Page 43: Removing An Hvac/Hvdc Power Supply

    Turn off the circuit breaker for the power feed to the power supply that you are replacing. Be sure that the LEDs turn off on the power supply that you are removing. Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 44: Installing An Ac Power Supply

    If the power supply does not fit into the open slot, turn the module over before sliding it carefully into the open Note slot. Step 2 Test the installation by trying to pull the power supply out of the slot without using the release latch. Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 45: Installing An Hvac/Hvdc Power Supply

    Step 3 If the DC power cables and a grounding cable are already connected to an electrical connector block, insert the block into the power receptacle on the power supply. Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 46: Installing A Dc Power Supply

    Verify that the power supply is operational by making sure that the power supply LED is green. For information on what the power supply LEDs indicate, see Power Supply LEDs, on page Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 47: Wiring A 48 V Dc Electrical Connector Block

    Orient the connector as shown in the following figure with the orange plastic button on top. Wire retainer lever -48V (-DC) cable Orange plastic button on top of the connector Grounding cable (8 AWG recommended) Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 48 "+ DC". Step 9 Verify that the other ends of the cables are attached to the DC power source and ground. You are then ready to turn on the DC power source. Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 49: Rack Specifications

    • Standard 19-inch (48.3 cm) (two- or four-post EIA cabinet or rack, with mounting rails that conform to English universal hole spacing per section 1 of ANSI/EIA-310-D-1992). For more information, see Requirements Specific to Perforated Cabinets, on page Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 50: Requirements Specific To Standard Open Racks

    • The roof should be perforated with at least a 20 percent open area. • The cabinet floor should be open or perforated to enhance cooling. The Cisco R Series rack conforms to these requirements. Cable Management Guidelines To help with cable management, you might want to allow additional space in the rack above and below the chassis to make it easier to route all of the fiber optic or copper cables through the rack.
  • Page 51: System Specifications

    Cisco Nexus 93600CD-GX Chassis 25 lb (11.3 kg) (N9K-C93600CD-GX) Fan Module — 6 (5 for operations and 1 for redundancy) – Port-side exhaust (blue) 0.26 lb (0.12 kg) (NXA-FAN-35CFM-PE) – Port-side intake (burgundy) (NXA-FAN-35CFM-PI) Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 52: Transceiver And Cable Specifications

    To determine the power consumption characteristics for the switch, use the typical and maximum requirements that are listed in the following table. Switch Typical Power Maximum Power Heat Dissipation Consumption (AC or DC) Consumption (AC or DC) Requirement Cisco Nexus 586 W 93600CD-GX Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 53: Power Specifications

    Form factor RSP1 1100-W HVAC/HVDC Power Supply Specifications These specifications apply to the following power supplies: • NXA-PHV-1100W-PE • NXA-PHV-1100W-PI Characteristic Specification Efficiency Input voltage 100VAC – 277VAC, 240VDC – 380VDC Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 54: 1100-W Dc Power Supply Specifications

    Power supply standby voltage 3.3 V/ 3A Efficiency rating @ -48VDC 94% at 50% load Power Cable Specifications The following sections specify the power cables that you can order and use with this switch. Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 55: Power Cable Specifications For Ac Power Supplies

    250 VAC, 10 A, MP232 plug, 8.2 feet (2.5 m) United Kingdom CAB-9K10A-UK 250 VAC, 10 A, BS1363 plug (13 A fuse), 8.2 (2.5 m) All except Argentina, Brazil, and NO-POWER-CORD No power cord included with Japan switch Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 56: Hvac/Hvdc Power Cables Supported By Aci-Mode And Nx-Os Mode Switches

    Saf-D-Grid and SD connectors CAB-HVAC-C14-2M HVAC 6.6-foot (2.0 m) cable with Saf-D-Grid and C14 connector (use for up to 240 V) CAB-HVAC-RT-0.6M HVAC 2-foot (0.6 m) cable with Saf-D-Grid and RT connector Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 57: Dc Power Cable Specifications

    The 1100W DC power supply (NXA-PDC-1100W-PE/PI) is shipped with a connector already plugged into the power supply. Regulatory Standards Compliance Specifications The following table lists the regulatory standards compliance for the switch. Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 58 • CNS13438 Class A EMC: Immunity • EN55024 • CISPR24 • EN300386 • KN 61000-4 series RoHS The product is RoH-6 compliant with exceptions for leaded-ball grid-array (BGA) balls and lead press-fit connectors. Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 59: Leds

    Temperature exceeds the minor alarm threshold. The switch is not receiving power. Green Fans and power supply modules are operational. Amber At least one fan or power supply module is not operating. Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 60: Fan Module Leds

    Power supply is not receiving power. Green Flashing amber Power supply warning—possibly one of the following conditions: • High voltage • High power • Low voltage • Slow power supply fan Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 61: Additional Kits

    • M4 x 8-mm Phillips pan-head screws (2) Not applicable EAC Compliance document Not applicable Hazardous substances list for customers in China The following table lists and illustrates the console cable (CAB-CONSOLE-RJ45) that can be ordered. Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...
  • Page 62 Additional Kits Additional Kits Illustration Description Quantity Console cable with DB-9F and RJ-45F connectors Cisco Nexus 93600CD-GX ACI-Mode Switch Hardware Installation Guide...