Frigidaire FNGD60JGR User Manual page 31

Table of Contents

Advertisement

BURNER
Grill
Gas burners for NATURAL GAS G20 20 mbar
BURNER
Triple Crown
Semi-rapid
Auxiliary
Oven
Grill
Gas burners for LPG G30 28-30 mbar
BURNER
Triple Crown
Semi-rapid
Auxiliary
Oven
Grill
Gas connection
The gas pipe in the appliance has two
endings. You can connect the gas supply to
either one of them. The pipe that is not
used must be clogged with the pipe closer,
which added to the appliance.
Use a fixed connections or use a flexible
stainless steel pipes in compliance with the
regulation in force. If you use flexible
metallic pipes, make sure they do not come
in touch with mobile parts and they are not
squeezed.
NORMAL POWER
KW
4.0
2.0
1.0
2.25
2.0
NORMAL POWER
KW
4.0
2.0
1.0
2.25
2.0
Ø BYPASS 1/100 MM
REDUCED POWER KW
1.80
0.45
0.35
1.0
1.5
REDUCED POWER KW
1.80
0.43
0.35
1.0
1.5
INSTALLATION
59
INJECTOR MARK
1/100 MM
146
96
70
108
108
INJECTOR MARK
1/100 MM
101
71
50
71
71
31