2.2 DMX Channel

In 5 channel mode
Channel
1
2
3
4
5
In 12 channel mode
Channel
1
2
3
4
5
6
7
8
9
10
11
12
13
3. Set up
Disconnect the power cord before replacing a fuse and always replace with the
same type fuse.
Power Supply: Before plugging your unit in, be sure the source voltage in your area matches
the required voltage for your. The Light is available in a 110v to 250v version. Because line
voltage may vary from venue to venue, you should be sure your unit voltage matches the wall
outlet voltage before attempting to operate you fixture.

3.1 Fuse replacement

With a flat head screwdriver wedge the fuse hold out of its housing. Remove the damaged
fuse from its holder and replace with exact same type fuse. Insert the fuse holder back in its
place and reconnect power.

3.2 Fixture linking

You will need a serial data link to run light show of one or more fixtures using a DMX-512
controller or to run synchronized on two or more fixtures set to a master/slave operating
mode. The combined number of channels required by all the fixtures on a serial data link
determines the number of fixtures the data link can support.
Maximum recommended serial data link distance: 500 meters (1640ft).
Maximum recommended number of fixtures on a serial data link: 32 fixtures.

Data cabling

To link fixtures together you must obtain data cables. If you choose to create your own cable
please use data-grade cables that can carry a high quality signal and are less prone to
electromagnetic interference.
PAN
TILT
DIMMER & STROBE
COLOR
BLANK
PAN
PAN FINE
TILT
TILT FINE
PAN/TILT SPEED
DIMMER & STROBE
RED
GREEN
BLUE
COLOR
COLOR SPEED
MOVEMENT(AUTO & SOUND EFFECT)