AIR CONDITIONER
INSTALLATION MANUAL
OUTDOOR UNIT
For authorized service personnel only.
INSTALLATIONSANLEITUNG
AUSSENGERÄT
Nur für autorisiertes Fachpersonal.
MANUEL D'INSTALLATION
APPAREIL EXTÉRIEUR
Pour le personnel d'entretien autorisé uniquement.
MANUAL DE INSTALACIÓN
UNIDAD EXTERIOR
Únicamente para personal de servicio autorizado.
MANUALE DI INSTALLAZIONE
UNITÀ ESTERNA
A uso esclusivo del personale tecnico autorizzato.
ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ
ΕΞΩΤΕΡΙΚΗ ΜΟΝΑΔΑ
Μόνο για εξουσιοδοτημένο τεχνικό προσωπικό.
MANUAL DE INSTALAÇÃO
UNIDADE EXTERIOR
Apenas para pessoal de assistência autorizado.
РУКОВОДСТВО ПО УСТАНОВКЕ
ВНЕШНИЙ МОДУЛЬ
Только для авторизованного обслуживающего персонала.
MONTAJ KILAVUZU
DIŞ ÜNİTE
Yalnızca yetkili servis personeli için.
PART No. 9316421073

Advertisement

loading

Summary of Contents for Fujitsu 9316421073

  • Page 1 ΕΞΩΤΕΡΙΚΗ ΜΟΝΑΔΑ Μόνο για εξουσιοδοτημένο τεχνικό προσωπικό. MANUAL DE INSTALAÇÃO UNIDADE EXTERIOR Apenas para pessoal de assistência autorizado. РУКОВОДСТВО ПО УСТАНОВКЕ ВНЕШНИЙ МОДУЛЬ Только для авторизованного обслуживающего персонала. MONTAJ KILAVUZU DIŞ ÜNİTE Yalnızca yetkili servis personeli için. PART No. 9316421073...
  • Page 2: Table Of Contents

    Do not attempt to install the air conditioner or a part of the air conditioner by yourself. INSTALLATION MANUAL This unit must be installed by qualifi ed personnel with a capacity certifi cate for handling 9316421073 refrigerant fl uids. Refer to regulation and laws in use on installation place. Contents The installation must be carried out in compliance with regulations in force in the place of installation and the installation instructions of the manufacturer.
  • Page 3: Selecting The Mounting Position

    Thicknesses of Annealed Copper Pipes 2.5. Additional charge Maximum height Nominal Outer Maximum Refrigerant suitable for a piping length of 15 m is charged in the outdoor unit at the factory. Thickness (between indoor and out- diameter diameter length When the piping is longer than 15 m, additional charging is necessary. door) Between 15 m and 20 m, when using a connection pipe other than that in the table, charge 1/4 in...
  • Page 4: Installation Diagram

    5.3. Outdoor unit wiring 4. INSTALLATION DIAGRAM (1) Remove the outdoor unit connector cover. (2) Bend the end of the cable as shown in the fi gure. INDOOR UNIT (3) Connect the end of the connection cable fully into the terminal block. (4) Fasten the sheath with a cable clamp.
  • Page 5 Strip Crimp-type terminal CAUTION 10 mm Fasten a fl are nut with a torque wrench as instructed in this manual. If fastened too tight, the fl are nut may be broken after a long period of time and cause a leakage of Sleeve refrigerant.
  • Page 6: Pump Down

    5.8. CUSTOMER GUIDANCE Explain the followings to the customer in accordance with the operating manual: (1) Starting and stopping method, operation switching, temperature adjustment, timer, airfl ow switching, and other remote controller operations. (2) Air fi lter removal and cleaning, and how to use the airfl ow direction louvers. (3) Give the operating and installation manuals to the customer.