Table of Contents

Advertisement

11.8.2 Defrosting time
At condition ①, If item B is satisfied before item A, it would be regarded as severe frosting and the defrosting
time is 10 minutes. If item B is satisfied after item A, the defrosting time is 7.5minutes.
At condition ②, the defrosting time is 10 minutes.
After three times continuous 7.5minute defrost, the fourth defrost time should be 10 minutes.
The circulation is as following:
11.8.3 Ending condition of defrosting
If one of following conditions is satisfied, end the defrost and turn into heating mode:
A. The defrost time has reached to 7.5 or 10 minutes.
B. The compressor current has reached to I
11.8.4 Defrosting Actions

11.9 Auto mode

11.9.1 The air conditioner automatically selects one of the following operation modes: cooling, heating or fan
only according to the temp erature d ifference between room temp erature (TA) and set temp erature (TS) .
11.9.2 The indoor fan blows automatically in corresponding selected mode
11.9.3 The motion of indoor fan's blade should accord with the selected operation mode
11.9.4 One mode should be carried out for at least 15 minutes once selected. If the compressor cannot start for
15 minutes, reselect the operation mode according to the room temp. and set temp., or reselect when the set
temp. varies
33
Service manual
or above, I
DEFROST
DEROST
differs in different models

Advertisement

Table of Contents
loading

Table of Contents