Dehumidifying Mode - Midea MSF3-07CRN2 Service Manual

Table of Contents

Advertisement

Auto fan at cooling mode:
Room temp. down
Anti-freezing control to indoor evaporator at cooling mode ( T: evaporator temp. )
EVAP. temp. down
Compressor and outdoor
fan off (after 5 mins)

11.6 Dehumidifying mode

11.6.1 The 4-way valve is off in dehumidifying mode
11.6.2 Compressor and Indoor Fan actions in dehumidifying mode
Indoor
Block
Fan
LOW
A
BREEZE OFF 4minutes
LOW
B
BREEZE OFF 5minutes
LOW
C
BREEZE OFF 6minutes
Repeat on and off cycle.
11.6.3 Low room temperature protection:
When room temperature decreases to below 10℃, compressor and outdoor fan will stop(indoor fan is Breeze).
Dehumidifying operation will be resumed when room temperature restores to over 13℃.
30
Mid. fan
Low fan
1
TE5
C
B
0
Compressor and Outdoor Fan
ON 6minutes
ON 5minutes
ON 4minutes
Service manual
3
5
T-Ts
Compressor and
outdoor fan on
EVAP. temp. up
TE6
A
2
High fan
Room temp. up
T
TA-TS

Advertisement

Table of Contents
loading

Table of Contents