Quiet Operation - Panasonic CS-A7HKD Service Manual

Hide thumbs Also See for CS-A7HKD:
Table of Contents

Advertisement

• The Fan Speed will shift as shown below:
• Vertical Airflow Direction:-
- In "Manual" setting, the vane will automatically shift down 5° lower than previous setting.
- In "Auto" setting, the vane will automatically shift between upper and lower limit depending on the intake air temperature as
Heating Mode, Airflow Direction Auto-Control. However the upper and lower limit will be shifted 5° downward.
• Powerful operation stops when:-
- Powerful operation has operate for 15 minutes.
- Powerful button is pressed again.
- Quiet button is pressed.
- Stopped by OFF/ON operation button.
- Timer OFF activates.
- Operation mode is changed.

12.10. Quiet Operation

(For Cooling Operation or cooling region of Soft Dry Operation)
• To provide quiet cooling operation condition compare to normal operation.
• Once the Quiet Mode is set at the remote control, the Quiet Mode LED illuminated. The sound level will reduce around 2 dB(A)
for Lo fan speed or 3 dB(A) for Hi/Me fan speed against the present operation sound level.
• Dew formation become severe at Quiet Lo cool, therefore Quiet Lo cool is operated only 1hr 30 min (1hr QLo, 30 min QLo + 50
rpm). After that, it goes back to Lo cool (However Quiet LED remains on).
• Manual Airflow Direction:-
- RPM control during Lo cool
39