8.2.

CS-A12HKD CU-A12HKD

Resistance of Indoor Fan Motor Windings
MODEL
CONNECTION
BLUE-YELLOW
YELLOW-RED
Note: Resistance at 25°C of ambient temperature.
Resistance of Outdoor Fan Motor Windings
MODEL
CONNECTION
BLUE-YELLOW
YELLOW-RED
Note: Resistance at 25°C of ambient temperature.
CS-A12HK
CWA921373
390.0 Ω
394.0 Ω
CU-A12HK
CWA951117J
230 Ω
255 Ω
19
Resistance of Compressor Windings
MODEL
CONNECTION
C - R
C - S
Note: Resistance at 20°C of ambient temperature.
CU-A12HK
2PS206D2BA02
3.207 Ω
3.256 Ω