Filter Replacement - Global Water G5CT Operation Manual

G5ct counter top
Table of Contents

Advertisement

The filter elements must be replaced at regular intervals to
maintain the quality of the water.
The G5CTF has 3-stages of mechanical filtration. 1st stage 5-
micron sediment filter, 2nd stage activated carbon filter and a 3
stage post carbon filter. The filter elements in all stages must be
replaced every 6 months.
The G5CTRO model has the 3-stages of filtration plus an
additional Reverse Osmosis membrane filter. The 3 pre filters must
be replaced every 6 months. The Reverse Osmosis membrane must
be replaced every 3 years.
Replacement Procedures, Filtration Versions (F) G5CTF
Coolers
a) TURN OFF POWER TO HOT/COLD ELEMENTS
b) Swing open the front hinged cover.
c) Close the ball valve to stop water flow through the filters.
d) Place a towel under the filters to catch water. The filters will
have water in them which will run out when the filters are
unlocked.
e) Twist the filters to remove them from their housings.
f) These filters are disposable, encapsulated filters. Remove and
discard the entire filter body. Replacement filters are sold as a
set:
1
Stage sediment filter
st
2
Stage carbon filter
nd
3
Stage post carbon filter
rd
f) Twist new filters on the housing brackets.
g) Open ball valve and let water flow through filters, when the
cooler is full empty out the water into a bucket. This will
eliminate the first batch of water which is full with carbon
fines.
h) After the cooler fills up again turn on the power to the cold
and hot tanks. Wait a few minutes to assure there are no leaks
and close the filter door.
17 |
P a g e

Filter Replacement

P/N TWSET
rd

Advertisement

Table of Contents
loading

Table of Contents