  • Page 1 MODEL G5 OPERATION MANUAL P a g e...
  • Page 2: Table Of Contents

    Reverse Osmosis Membrane Replacement.…………………………………….……pg.20 Troubleshooting……………………………………….………………………………………..pg.21 Specifications………………………………………….………………………………………..….pg.22 Warranty……………………………………………………….……………………………………..pg.22 List of Figures Figure 1. Assembly Drawing, Model G5………………...….…………………………….pg.5 Figure 2. Faucet Operation…………………………….….………..………………………….pg.6 Figure 3. Hot/Cold Power On/Off Switch.……….….……………..……………………pg.6 Figure 4. Water Cooler Connections………………...…………………………………..pg.11 Figure 5. Drain Connections for “RO” Models……………………………….……...pg.13 Figure 6. Filter Configuration Model “F”……………………………………………….pg.15 Figure 7.
  • Page 3: Introduction

    We manufacture a wide range of models to fit any home or office application. The G5 Model has 3 temperature faucets; cold water is chilled around 44ºF, hot water is heated at 180ºF and ambient.
  • Page 4: Receiving

    Description Model G5 The G5 Model provides water at 3 different temperatures, dispensed from three spigots, “hot”, “cold” and ambient. The assembly drawing is shown in Figure 1. Water flows from the filter system into the ambient tank and the cold water tank simultaneously.
  • Page 5: Description Model G5

    Description Model G5 Figure 1. Assembly Drawing Model G5 P a g e...
  • Page 6: Operation

    Operation When installation is complete, the unit will fill up with water and shut off when the tanks are full. Plug the unit in to an outlet and press the cold/hot faucets until a steady stream of water comes out. Figure 2.
  • Page 7 Operation Cont… P a g e...
  • Page 8: Drain Container Operation

    Drain Container Operation P a g e...
  • Page 9: Cup Dispenser Operation

    Cup Dispenser Operation P a g e...
  • Page 10: Positioning The Cooler

    Positioning the Cooler 1) It is not recommended to install this cooler in an area were water may cause severe or costly damage. 2) Do not position the cooler where it can be hit or bumped by Vacuum cleaners or floor waxing machines. This can cause breaks in the waterline, connection fittings and compressor tubing.
  • Page 11: Water Cooler Connections

    Water Cooler Connections When you receive the water cooler, the water connections on the back have of the cooler have tube plugs in them. These tube sections must be removed before making all your connections. To remove the tube sections see figure 7 “Disconnect”. The 1/4" plastic tubing should be used for making the Feed Water and Drain connections.
  • Page 12: Feed Water Connection

    Feed Water Connections To connect the feed water, use the supplied self-piercing saddle valve to connect to the cold water supply line under the sink. Attach the 1/4-inch tubing to the compression fitting on the side of the valve. Clamp the saddle valve over copper or plastic feed line (cold water only).
  • Page 13: Drain Connection

    Drain Connection (Applies to models with Reverse Osmosis “RO” only) The drain line in the back (Fig. 4) must be hooked to the drain line ahead of the normal sink water trap. See Figure 5 below. Place the 2 part drain saddle on the drain pipe before the drain trap.
  • Page 14: Ez Connections

    EZ Connections The standard tubing connections on the water coolers are EZ connect fittings. Use the tubing and follow the instructions below in fig. 7 to make the connections. If you cut the tubing, make sure it is a square cut, fits squarely in the fitting and seals properly.
  • Page 15: Start Up Flush

    Start-Up Flush Open lower front door to access filter assembly, turn the water on at the at the water connection, this brings water to the ball valve. Disconnect the tube from the 2nd stage carbon filter (circle in figure below) and place a cup or pan right underneath the hole to catch water. Open ball valve inside the cooler 1/4-turn (handle in line with tube is “on”...
  • Page 16: Tank Flush

    ‘RO’ version, about 10-15 minutes for the ‘F’ version. Observe the water level when full, and see that water input to the tank stops when it is full. Figure. 7 Back view of the Cooler Water Connections Model G5 16 | P a g e...
  • Page 17: Cleaning And Maintenance

    Cleaning and Maintenance 17 | P a g e...
  • Page 18 Sanitize Fill main water tank with water. Add 1-2 teaspoons of liquid chlorine bleach. Let stand for 5-10 minutes. Drain the water then let water from filters refill tank and drain a second time. Remember to drain from dispensing spigots also. Note: Upon completion of cleaning, wait at least 10 minutes after the power cord is plugged in before turning on the Hot and Cold Water buttons.
  • Page 19: Filter Replacement

    Filter Replacement The filter elements must be replaced at regular intervals to maintain the quality of the water. The G5F has 3-stages of mechanical filtration. 1st stage 5-micron sediment filter, 2nd stage activated carbon filter and a 3 stage post carbon filter.
  • Page 20: Reverse Osmosis Membrane Replacement

    Reverse Osmosis Membrane Replacement (every 3 years) RO versions (RO) a) Use the same procedure as above sec a-c. b) Remove the RO stage from the clips. Disconnect the white tubing from the RO housing cap. c) Remove the cap from the housing by unscrewing it. d) Using a pair of pliers, remove the RO element from the housing by grasping the tube end and pulling it out.
  • Page 21: Troubleshooting

    Trouble Shooting Guide PROBLEM CAUSE SOLUTION No Power No electric current Make sure the cooler flowing. is plugged in and check for improper connections. Cold Water not cold The cooler is placed Provide a minimum of 5” space between wall enough too close to the wall.
  • Page 22: Specifications

    Specifications Model No. Voltage/Frequency AC110V Dimensions (L)14 x (W)13 x (H)48 Weight (empty) 70 lb. Hot Tank Capacity .5 gal. Ambient Tank Capacity Cold Tank Capacity 1 gal. Power Consumption Hot Water: 500W Cold Water: 100W Electric Power Cord Length 6Ft.
  • Page 23: Warranty

    Warranty All Global Water products are warranted to be free from defects in materials and workmanship under normal use within the condition of operation listed for a period of 1 year from date of purchase. The compressor has a 3-year warranty.
  • Page 24 Cleaner, Healthier Water. 2031 SW 31 Ave, Hallandale, Florida 33009 www.GlobalWaterInc.com Tel. (786) 235-2518 Fax (786) 207-2570 Email GlobalWaterFlorida@Gmail.com 24 | P a g e...