NEC Express5800/B120b-d User Manual page 164

Table of Contents

Advertisement

8-6 Troubleshooting
On-screen error message
8450
Can't Read FRU on CPU Unit Type I Mezzanine
8451
Can't Read FRU on CPU Unit Type II Mezzanine
Expansion Rom not initialize
Invalid System Configuration Data
Resource Conflict
System Configuration Data Read error
System Configuration Data Write error
WARNING: IRQ not configured
IMPORTANT:
displayed due to insufficient expansion ROM area. Select one of the
features of the lowest frequency and set it to "Disabled".
– On board LAN 1/On board LAN 2
– PCI slot 1
The message "Expansion Rom not initialized" may be
Action
Power off and reboot the CPU blade.
Also make sure the mezzanine card is
correctly installed in Type I mezzanine
card slot.
If the error persists, contact your service
representative.
Power off and reboot the CPU blade.
Also make sure the mezzanine card is
correctly installed in Type II mezzanine
card slot.
If the error persists, contact your service
representative.
Run the BIOS SETUP utility to disable
the use of expansion ROM area and PCI
slot OptionROM. If the error persists,
contact your service representative.
Contact your service representative.

Advertisement

Table of Contents
loading

Table of Contents