Setup

6 • SmarTouch™ IR Wireless Touchpanel: ST-1700CIR

Applying Power

The touchpanel can be powered via the supplied external AC power pack, the
ST-DSN docking station, or the ST-BTPN battery pack. Each of these supplied items
has its own guide which details proper usage. Refer to the following table for the
required document number.
NOTE: The battery can be charged only if the touchpanel is in the docking station.
The touchpanel will function when powered by the external power pack, but this
configuration will not charge the battery.
NOTE: The touchpanel will not transmit IR commands unless the battery is installed
and charged.
ST-1700CIR Power Source Options
POWER SOURCE OPTION
2
Battery Pack
Docking Station
Domestic External Power Pack or
International External Power Pack
1
The latest revision may have a revision letter after the document number (e.g., 6088A)
2
The battery pack does not "trickle" charge when the external power pack is used to power the
touchpanel.

Identity Codes

The ST-1700CIR touchpanel uses two distinct types of identity codes: Cresnet
identity (Net ID or Cresnet ID), and IR ID. These codes are assigned to the
touchpanel from an interface submenu when the unit is configured. Refer to "Setup
Menu" on page 7. For the touchpanel to be identified within the Cresnet system,
these assignments must match assignments made in the SIMPL Windows program.
Net ID
Every equipment and user interface within the Cresnet system requires a unique Net
ID. The Net ID is a two-digit hexadecimal number that can range from 03 to FE. The
Net ID is used when the touchpanel is wired directly to the control system during
uploading a Crestron VisionTools
touchpanel firmware. The Net ID of the ST-1700CIR has been factory set to 03.
IR ID
Every ST-1700CIR touchpanel communicating with a Cresnet control system via a
CNXRMIRD or C2N-IRGW-1G requires a unique IR ID to secure IR
communications. There are two useable codes (two-digit hexadecimal numbers): 00
and 10; the default is 00. The IR ID of the unit must match the IR ID specified in the
SIMPL Windows program.
Crestron ST-1700CIR
MODEL
ST-BTPN
ST-DSN
PW-1215
PWI-1215
®
Pro-e (VT Pro-e) project or upgrading the
Operations Guide – DOC. 6469
DOCUMENT
1
NUMBER
6088
6095
5762
5763
.
®