UPA-200
Gain:
29 dB.
Input Connections:
Unbalanced (RCA); one per channel.
Input Impedance:
47 kOhms.
Trigger:
Trigger Input: 5 - 20 V (AC or DC); < 10 mA input current required.
Trigger Output: 12 VDC; can drive any load up to 50 mA.
Power Requirements:
115 VAC or 230 VAC +/- 10% @ 50 / 60 Hz (automatically detected and switched).
Front Panel Controls and Indicators:
Standby; push button (changes color to indicate Standby or On).
Status LEDs (one per channel); illuminate blue for normal operation or red to indicate a fault
(may be disabled by rear panel Status LED switch).
Rear Panel Controls:
AC Power switch; rocker switch (switches AC mains power).
Status LEDs switch; small slide switch on left rear (disables front panel Status LEDs).
Protection:
The UPA-200 is protected against excessive operating temperature, shorted speaker
connections, ground faults, and other common fault conditions. If a fault occurs, the UPA-
200 will return to Standby mode, the Standby push button will light amber, and the Status
LEDs will flash red.
Dimensions:
17" wide x 3.375" high x 16.5" deep (includes feet and binding posts).
Weight:
24 lbs (net); 32 lbs (packaged).