Specifications

Maximum Length
8,000 feet (2,438 meters) on certain cable types, 4,000 feet (1,220 meters) on most cable
types, and 500 feet (152 meters) on cables with high loss. The tester shows -
too long to be correctly measured.
Representative
8,000 feet (2,438 meters): CAT-3 Twisted Pair
Maximum Cable
8,000 feet (2,438 meters): CAT-5 Twisted Pair
Length
6,000 feet (1,830 meters): 12/2 AC Wire
3,000 feet (900 meters): RG-6/U TV Coax
1,500 feet (457 meters): RG-174/U Coax
Minimum Length
No minimum length. Minimum non-zero reading is 2 feet or1 meter
Length Accuracy
±2 feet (±0.6 m) for cables less than 10 feet (3 m)
±5 feet (±2 m) for cables longer than 10 feet (3 m) and shorter than 200 feet (60 m)
±3%, ±5 feet (±2 m) for cables longer than 200 feet (60 m)
Distance to Bridge
0 feet to 3,200 feet (975 meters)
Tap
20
Caution
or any similar
®
Table 4. Accessories
Description

Accessories

Table 4 shows the accessories available for the TS100
PRO tester. For the latest list of accessories, visit the
Fluke Networks website.
LEAD-ABNP-100
LEAD-ALIG-100
LEAD-ABN-100
CASE-TS-100
Fluke Networks
Model Number
if the cable is
Err