Fluke TS 100 PRO User Manual page 17

Cable fault finder
Table of Contents

Advertisement

In the warehouse, you can quickly measure the cable
remaining on all your spools, allowing you to select the
right spool for each job. Additionally, by keeping a
record of the prior inventory, you can determine how
much wire was used on the current job.
The TS100 PRO works on two conductors. You
cannot use the tester to measure single-
conductor cable.
Table 2. VOP Values and Maximum Length for
Specifically Identified Cables
Maximum
VOP
Length
64
2000 ft
(610 m)
63
1500 ft
(460 m)
61
2000 ft
(610 m)
60
1500 ft
(460 m)
58
1000 ft
(300 m)
66
2500 ft
(770 m)
68
2500 ft
(770 m)
Note
Cable
Lucent 1024 006ABE 6/24
W1000, 6 pair CAT3 (Blue-
White)
BICC General Aerial
Service Wire (ASW) 2/22, 2
Pair Drop Wire
Superior Essex, 4 pair
CAT3 Plenum (not pair
dependent)
BICC General, 24 AWG
CMX Outdoor CMR
Station Wire
BICC General cross-
connect 24 AWG twisted
pair on original spool
Berk-Tek, CAT5 (Orange-
White)
Superior-Essex Cobra
CAT5 CMR (Orange-
White)
Table 2. VOP Values and Maximum Length for
Specifically Identified Cables (continued)
Maximum
VOP
Length
72
2500 ft
(770 m)
82
1000 ft
(300 m)
81
1000 ft
(300 m)
79
1000 ft
(300 m)
67
500 ft
(150 m)
68
500 ft
(150 m)
64
500 ft
(150 m)
57
500 ft
(150 m)
73
1000 ft
(300 m)
71
2000 ft
(610 m)
67
2000 ft
(610 m)
Applications
Cable
Superior-Essex Cobra
CAT5 CMP (Orange-
White)
CommScope 5726, RG6
CATV Coax
CommScope 2275V, RG6
CATV Coax
CommScope 5571, RG59,
TV Coax
Belden 88760 2 wire
shielded 18 AWG, Red-
Black
Belden 88760 2 wire
shielded 18 AWG, Red/
Black-Shield
Carol C1156 RG-174/U
BICC General, E22025,
Red-Black
Channel Master Polyclad
Model 9354 300 Ohm
Foam Antenna Wire
Triangle Wire and Cable,
type NM-B 12/2 W/G,
Black-Ground
Triangle Wire and Cable,
type NM-B 12/2W/G,
Black-White
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents