elsner elektronik KNX R Installation And Adjustment

elsner elektronik KNX R Installation And Adjustment

Rain sensor
Hide thumbs Also See for KNX R:

Advertisement

Quick Links

EN
KNX R
Rain Sensor
Installation and Adjustment

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KNX R and is the answer not in the manual?

Questions and answers

Summary of Contents for elsner elektronik KNX R

  • Page 1 KNX R Rain Sensor Installation and Adjustment...
  • Page 2: Table Of Contents

    5.2.3. OR Logic 1 / 2 / 3 / 4 ..................18 5.2.4. Linkage inputs of OR logic ................. 18 Elsner Elektronik GmbH • Herdweg 7 • D-75391 Gechingen • Germany Rain Sensor KNX R • from software version 1.00, ETS programme version 1.1 Errors excepted. Subject to technical changes.
  • Page 3 Content Elsner Elektronik GmbH • Herdweg 7 • D-75391 Gechingen • Germany Rain Sensor KNX R • from software version 1.00, ETS programme version 1.1 Errors excepted. Subject to technical changes.
  • Page 4: Description

    24 V DC version max. 100 mA, Residual ripple 10% Data output KNX +/- bus terminal plug BCU type Own micro controller PEI type Group addresses max. 254 Rain Sensor KNX R • Date of issue: 05.11.2010 • Technical changes reserved. Errors reserved.
  • Page 5: Installation And Commissioning

    The device must only be operated as stationary system, i.e. only in a fitted state and after completion of all installation and start-up works, and only in the environment in- tended for this purpose. Rain Sensor KNX R • Date of issue: 05.11.2010 • Technical changes reserved. Errors reserved.
  • Page 6: Location

    The sensor comes with a combination wall/pole mount. The mount comes adhered by adhesive strips to the rear side of the housing. Fasten the mount vertically onto the wall or pole. Rain Sensor KNX R • Date of issue: 05.11.2010 • Technical changes reserved. Errors reserved.
  • Page 7 Fig. 6 Example uses of the hinge arm mounting: With the hinge arm mounting, the sensor peeps out from beneath the roof overhang. Rain Sensor KNX R • Date of issue: 05.11.2010 • Technical changes reserved. Errors reserved.
  • Page 8: View Of Rear Side And Drill Hole Plan

    Fig. 8 a+b Drill hole plan Dimensions of rear side of housing with bracket. Sub- ject to change for technical enhancement. Langloch 7,5 x 5 mm Rain Sensor KNX R • Date of issue: 05.11.2010 • Technical changes reserved. Errors reserved.
  • Page 9: Preparing The Sensor

    Push the bus connection cable through the rubber seal on the bottom of the sensor and connect bus +/- to the provided clamps. For 24V devices the connection cable must be plugged in between the cover and circuit board. Rain Sensor KNX R • Date of issue: 05.11.2010 • Technical changes reserved. Errors reserved.
  • Page 10: Pcb Layout

    4) Slot for KNX clamp +/- Opening for the bus cable 6) Programming pushbutton for the teach-in of the device 7) Programming LED Rain Sensor KNX R • Date of issue: 05.11.2010 • Technical changes reserved. Errors reserved.
  • Page 11: Mounting The Sensor

    Fig. 12 Make sure the cover and bottom part are pro- perly snapped together! This picture is loo- king at the closed sensor from underneath. Fastening Rain Sensor KNX R • Date of issue: 05.11.2010 • Technical changes reserved. Errors reserved.
  • Page 12: Notes On Mounting And Commissioning

    As a precaution, the device should always be separated from power supply for maintenance works (e.g. deactivate or remove fuse). Rain Sensor KNX R • Date of issue: 05.11.2010 • Technical changes reserved. Errors reserved.
  • Page 13: Transmission Protocol

    Switching Output C R T OR Logic 4 8 bit Output A C R T OR Logic 4 8 bit Output B C R T Rain sensor KNX R • Date of issue: 19.01.2011 • Technical changes reserved. Errors reserved.
  • Page 14 C R W Logic Input 6 Input C R W Logic Input 7 Input C R W Logic Input 8 Input C R W Software Version readable Rain sensor KNX R • Date of issue: 19.01.2011 • Technical changes reserved. Errors reserved.
  • Page 15: Setting Of Parameters

    5 sec … 2 h (only if sending “cyclically”) Maximum telegram quota 1 • 2 • 3 • 5 • 10 • 20 Telegrams per second Rain sensor KNX R • Date of issue: 19.01.2011 • Technical changes reserved. Errors reserved.
  • Page 16: Logic

    Logic 1 / 2 / 3 / 4 not active • active Transmission delay of switching outputs 5 secs … 2 h after power up and programming Rain sensor KNX R • Date of issue: 19.01.2011 • Technical changes reserved. Errors reserved.
  • Page 17 Logic output sends one 1 bit object if logic = 1 object value 1 • 0 if logic = 0 object value 1 • 0 Rain sensor KNX R • Date of issue: 19.01.2011 • Technical changes reserved. Errors reserved.
  • Page 18: Linkage Inputs Of And Logic

    Communication object logic input 5 inverted Communication object logic input 6 Communication object logic input 6 inverted Communication object logic input 7 Communication object logic input 7 inverted Rain sensor KNX R • Date of issue: 19.01.2011 • Technical changes reserved. Errors reserved.
  • Page 19: Or Logic 1 / 2 / 3 / 4

    The OR logic is additionally provided with the following inputs: AND logic output 1 AND logic output 1 inverted AND logic output 2 AND logic output 2 inverted AND logic output 3 Rain sensor KNX R • Date of issue: 19.01.2011 • Technical changes reserved. Errors reserved.
  • Page 20 Setting of parameters AND logic output 3 inverted AND logic output 4 AND logic output 4 inverted Rain sensor KNX R • Date of issue: 19.01.2011 • Technical changes reserved. Errors reserved.
  • Page 21 Elsner Elektronik GmbH Control and Automation Technology Herdweg 7 D – 75391 Gechingen Phone +49 (0) 70 56 / 93 97-0 info@elsner-elektronik.de Germany +49 (0) 70 56 / 93 97-20 www.elsner-elektronik.de...