elsner elektronik KNX T-B-UP Technical Specifications And Installation Instructions

elsner elektronik KNX T-B-UP Technical Specifications And Installation Instructions

Temperature sensor

Advertisement

Quick Links

KNX T-B-UP
Temperature sensor
Technical specifications and installation instructions
Article numbers 70358, 70359, 70360, 70361
EN
Elsner Elektronik GmbH Control and Automation Engineering
Sohlengrund 16
D - 75395 Ostelsheim Phone +49 (0) 70 33 / 30 945-0 info@elsner-elektronik.de
Germany
Fax
+49 (0) 70 33 / 30 945-20 www.elsner-elektronik.de
echnical Service: +49 (0) 70 33 / 30 945-250
T

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KNX T-B-UP and is the answer not in the manual?

Questions and answers

Summary of Contents for elsner elektronik KNX T-B-UP

  • Page 1 KNX T-B-UP Temperature sensor Technical specifications and installation instructions Article numbers 70358, 70359, 70360, 70361 Elsner Elektronik GmbH Control and Automation Engineering Sohlengrund 16 D - 75395 Ostelsheim Phone +49 (0) 70 33 / 30 945-0 info@elsner-elektronik.de Germany +49 (0) 70 33 / 30 945-20 www.elsner-elektronik.de...
  • Page 2 (composite result) together with its own data. The KNX T-B-UP features two but- tons that may be used to modify the room temperature (nominal temperature), to switch between the operating modes or as freely programmable bus buttons.
  • Page 3: Technical Specifications

    ±1.5°C at -40…+45°C , page 4 * Please note the information on Measuring accuracy The product is compliant with the provisions of EU guidelines. Temperature sensor KNX T-B-UP • Software version 3.1 and higher Status: 21/03/2016 • Technical changes and errors excepted.
  • Page 4: Installation And Start-Up

    Elsner Elektronik is not liable for any changes in norms and standards which may occur after publication of these operating instructions.
  • Page 5: Construction Of The Sensor

    Fig. 1 Baseplate Catches Openings for air circulation Programming LED (recessed) Programming button (recessed) for teaching the device Openings for air circulation Temperature sensor KNX T-B-UP • Software version 3.1 and higher Status: 21/03/2016 • Technical changes and errors excepted.
  • Page 6: Notes On Mounting And Commissioning

    The manually adjustable range can be set in the ETS. Temperature sensor KNX T-B-UP • Software version 3.1 and higher Status: 21/03/2016 • Technical changes and errors excepted.
  • Page 7 Comfort mode. Standby mode. Comfort (present) target temper- Standby (absent during day) tar- ature will be used. get temperature will be used. Temperature sensor KNX T-B-UP • Software version 3.1 and higher Status: 21/03/2016 • Technical changes and errors excepted.
  • Page 8: Change Ambient Temperature With The Buttons

    Ambient temperature in the current temperature (+) right button mode is increased. The sep-size is defined in the ETS (0.1°C to 5°C). Temperature sensor KNX T-B-UP • Software version 3.1 and higher Status: 21/03/2016 • Technical changes and errors excepted.
  • Page 9 2 secs. evening). The period is defined in the ETS (up to 10 hours). The time remaining in Comfort mode is displayed. Temperature sensor KNX T-B-UP • Software version 3.1 and higher Status: 21/03/2016 • Technical changes and errors excepted.

This manual is also suitable for:

70358703597036070361