Quick Links

Manual Test
1 1
2 2
Lens Removal
1
1
2 2
3
Battery Replacement
It can be done only by a competent person and after the mains interruption.
1. Follow step 1 of the installation instructions and remove the diffusor.
2. Follow step 2 of the installation instructions and remove the reflector.
3. Remove the old battery and place a new one of the same type and characteristics.
4. Replace the removed parts (previous steps 1 and 2).
NOTE: LED= Light Emitting Diode
LABELING EXPLANATION:
X: Self contained
1: Maintained operation (*)
A: Including test device
B: Including remote test mode
C: Including inhibiting mode
F: Automatic test gear complying with IEC 61347-2-7 denoted EL-T
G: Internally illuminated safety sign
60: 1 hour duration
180: 3 hours duration
480: 8 hours duration
(*) Maintained operation: The luminaire lights its illumination source, when it is powered by the
mains power supply or not.
Non Maintained operation: The luminaire lights its illumination source, only in mains power supply's
failure.
NOTE!! The installer should fill in, on the specification label, the letter G if the luminaire is used as a
safety sign.
ATTENTION!!!
The light source contained in this luminaire shall only be replaced by the manufacturer, or
his agent, or a similar qualified person.
NOTE!! The light source is non-user replaceable.
CAUTION : Do not view directly with bare eyes.
4
Technical Characteristics
OPERATION VOLTAGE
MAXIMUM POWER CONSUMPTION
SUPPLY CURRENT
U-OUT
Prated
Irated
MAX OPEN CIRCUIT VOLTAGE
WIRE CROSS SECTION
MINIMUM POWER FACTOR
BATTERY (Ni-Cd)
INSULATION BETWEEN SUPPLY & CONTROL TERMINALS
BATTERY PROTECTION
MIN MAX. DISCHARGE VOLTAGE
MIN MAX. DISCHARGE CURRENT
MIN MAX. CHARGE CURRENT
TRICKLE CHARGE VOLTAGE/CURRENT
MAX CHARGE VOLTAGE
INDICATIONS
CHARGE TIME
MINIMUM DURATION
LIGHT SOURCE
LIGHT SOURCE LUMINOUS FLUX (MAINS / EMERGENCY)
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
VIEWING DISTANCE (as safety sign)
CONTROL GEAR MAX. TEMPERATURE:tc
OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY
CONSTRUCTION MATERIAL
EXTERNAL DIMENSION (L x W x H)
WEIGHT
GUARANTEE
CONTROL GEAR WITH AUTOMATIC
TEST FUNCTION
LED Characteristics
MANUFACTURER
MODEL NUMBER
VOLTAGE RANGE
NOMINAL POWER
CONNECTIONS
TEMPERATURE (tc)
Warranty
Olympia Electronics guarantees the quality, condition and operation of the goods. The period of warranty
is specified in the official catalogue of Olympia Electronics and also in the technical leaflet, which
accompanies each product. This warranty ceases to exist if the buyer does not follow the technical
instructions included in official documents given by Olympia Electronics or if the buyer modifies the goods
provided or has any repairs or re-setting done by a third party, unless Olympia Electronics has fully agreed
to them in writing. Products that have been damaged can be returned to the premises of our company for
repair or replacement, as long as the warranty period is valid.
Olympia Electronics reserves the right to repair or to replace the returned goods and to or not charge the
buyer depending on the reason of defection. Olympia Electronics reserves the right to charge or not the
buyer the transportation cost.
X 1
A
B C
F
6 0
G
5
923100401_09_002
OLY-1004/WP/ADR
220-240V AC / 50-60Hz
4.5W / 4.7VA
19mA
22V
1h: 2W
3h: 1.6W
8h: 0.6W
1h: 174mA
3h: 145mA
8h: 47mA
22V
2
2
0.5mm - 2.5mm
0.95
3.6V/3 Ah
Basic insulation
Deep discharge and overcharge protection / the control gear will recharge the battery normally after the test of 22.3
3-4.5V
1h: 510-885mA
3h: 410-715mA
8h: 138-220mA
190-210mA
100mA
6V
LED Charge, Lamp Fault LED, Battery Fault LED
24 hours
1 h, 3 h, 8 h
28 white LEDs
300lm / 350lm (1 h), 295lm (3 h), 95lm (8 h)
IP65
EN 60598-1, EN 60598-2-22, ΕΝ 55015,
ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3
25m
o
50 C at R18/R19
o
5 to 40 C
Up to 95%
ABS/PC, PC
270 x 147 x 48 mm
770gr.
3 years (1 year for the battery)
OLY-1004/WP/ADR
Olympia Electronics S.A.
2701205
10-12V DC
1h: 2W
3h: 1.6W
8h: 0.6W
Non reversible connection between main pcb and led module
50 °C max. across the board
72nd km. O.N.R. Thessaloniki-Katerini
P.C. 60300 P.O. Box 06 Εginio Pierias Greece
www.olympia-electronics.gr
info@olympia-electronics.gr
Warranty
923100401_09_002
European
manufacturers
OLY-1004/WP/ADR
ADDRESSABLE WATERPROOF SELF TESTING
MAINTAINED/NON MAINTAINED
EMERGENCY LUMINAIRE
Μ
NM
ADR
Duration
Light output
Non
IP65
25m
Addres-
Maintained
1h/3h/8h
maintained
350/295/95lm
sable
Thank you for your trust in our products
Olympia Electronics - European manufacturer

Advertisement

loading

Summary of Contents for olympia electronics OLY-1004/WP/ADR

  • Page 1 Non Maintained operation: The luminaire lights its illumination source, only in mains power supply’s sable Olympia Electronics reserves the right to repair or to replace the returned goods and to or not charge the failure. buyer depending on the reason of defection. Olympia Electronics reserves the right to charge or not the NOTE!! The installer should fill in, on the specification label, the letter G if the luminaire is used as a buyer the transportation cost.
  • Page 2 Package Contents Installation Instructions Attention!! The 6 plastic Luminaire latches (A) must be secured Set of Pictograms (click sound). This Mounting accessories Manual requirement is important to ensure the IP65 rating. General Power on the luminary. These devices are used indoors and outdoors of the luminaire.

This manual is also suitable for:

2701205