Controlling the Monitor with a PC (RS-232C)
Initialization/Functional Restriction Setting (FUNCTION) menu
Function
ALL RESET
ADJUSTMENT LOCK
ADJUSTMENT LOCK TARGET
OSD DISPLAY
LED
TEMPERATURE ALERT
POWER BUTTON
EXTERNAL CONTROLLER INPUT
STATUS ALERT
Others
Function
SCREEN SIZE (PC)
SCREEN SIZE (AV)
VOLUME
MUTE
INFORMATION
MODEL
SERIAL NO
TEMPERATURE SENSOR
TEMPERATURE ACQUISITION
CAUSE OF LAST STANDBY MODE
Commands for setting of the GAMMA user data
Function
RED GAMMA DATA TRANSFER
GREEN GAMMA DATA TRANSFER
BLUE GAMMA DATA TRANSFER
RED GAMMA DATA READ
GREEN GAMMA DATA READ
BLUE GAMMA DATA READ
USER DATA INITIALIZE
USER DATA SAVE
44
E
Command
Direction
Parameter
RSET
W
0-1
ALCK
WR
0-2
ALTG
WR
0-2
LOSD
WR
0-2
OFLD
WR
0-1
TALT
WR
0-2
PBTN
WR
0-1
PCIP
WR
0-4
SALT
WR
0-2
Command
Direction
Parameter
WIDE
WR
1-5
WIDE
WR
1-5
VOLM
WR
0-31
MUTE
WR
0-1
INF1
R
SRNO
R
DSTA
R
ERRT
R
STCA
W
0
R
Command
Direction
Parameter
UGRW
W
aaxxxx ··· xxxxcc
(xxxx: 32 pieces)
UGGW
W
aa: 01-16
UGBW
W
xxxx: 0000-1023
cc: 00-FF
UGRR
W
1-16 xxxx ··· xxxx
UGGR
W
1-16
UGBR
W
1-16
UGRS
W
UGSV
W
Reply
0: ALL RESET 1, 1: ALL RESET 2
0-2 0: OFF, 1:ON1, 2:ON2
0-2 0: REMOTE CONTROL, 1: MONITOR BUTTONS, 2: BOTH
0-2 0: ON1, 1: OFF, 2: ON2
0-1 0: ON, 1: OFF
0-2 0: OFF, 1: OSD & LED, 2: LED
0-1 0: MONITOR, 1: CONTROLLER
0-4 0: D-SUB, 1: DisplayPort, 2: HDMI1, 3: HDMI2, 4: DVI-I
("ERR" when MONITOR is selected for POWER BUTTON.)
0-2 0: OFF, 1: OSD & LED, 2: LED
Reply
1-5 1: WIDE, 2: NORMAL, 3: Dot by Dot, 4: ZOOM1, 5: ZOOM2
1-5 1: WIDE, 2: ZOOM1, 3: ZOOM2, 4: NORMAL, 5: Dot by Dot
0-31
0-1 0: OFF, 1: ON
Value
Value
0 Internal temperature normal
1 Internal temperature abnormal has occurred and the monitor is in standby mode
2 Internal temperature abnormal occurred (To delete the information of temperature
abnormal, turn off the main power.)
3 Internal temperature abnormal has occurred and backlight brightness is dimmed
4 Temperature sensor abnormal
Value Returns the temperature at the temperature sensors.
Indicates a temperature sensor abnormality when "126" is returned.
Initialization
0 No detectable error has occurred
1 Standby mode by POWER button
2 Main power off by the main power switch
3 Standby mode by RS-232C or LAN
4 Input signal waiting mode by No Signal
6 Standby mode by abnormal temperature
8 Standby mode by SCHEDULE setting
20 Standby mode by OFF IF NO OPERATION setting
Reply
aa: Block number
xxxx: 32 pieces of user data
cc: Checksum (ASCII data) of the block number and user data
xxxx: User data of 32 pieces
(xxxx: 32 pieces)
xxxx: 0000-1023
0
Initialize the user data.
0
Save the user data in the monitor.
Control/Response contents
Control/Response contents
Control/Response contents
*
-
*
-
*