outward. Push the lever down and the plunger retracts inwards.
8. Replace the rear fairing and dust cover.

Side Probe lock cam lever

1.
Remove the two countersunk bolts securing the right-side cover.
Figure 17: Right-side cover rear bolt location
2. Push the cam lever down and carefully prise away the side cover from the chassis.
3. Remove the four socket cap bolts securing the rear probe lever to the chassis.
4. Remove the side probe lever, the black plunger and metal spring washer from the scanner.
5. Install a new plunger together with the spring washer into recess in the chassis and re-install
the cam lever in the same orientation. Secure using the four socket cap bolts.
6. Check the operation of the probe lock cam lever. Lift the lever up and the plunger pushes
outward. Push the lever down and the plunger retracts inwards.
7. Replace the right-side cover.
Figure 19: Prising off the right side cover
Figure 20: Uni-directional scanning pattern
Figure 21: Cam lever with plunger and metal spring washer
Figure 18: Right-side cover front bolt location