Jayco Greyhawk Owner's Manual page 71

Table of Contents

Advertisement

I
CAUTION - PRODUCT DAMAGE
DO NOT allow flue gas exhaust to have extended contact with the exterior sidewall of the
recreation vehicle. It will cause the material to degrade over time. Exhaust tube and furnace
chamber tube must overlap no less than 1-1/4" and be positioned against the door screen for
proper function.
I
WARNING: FIRE OR EXPLOSION
Use the correct gas specified for your furnace.
Only a qualified Service Technician may convert a 8900 series furnace
from LP to NAT or NAT to LP.
All models, except the 8900 AC-III Series, are designed for LP GAS ONLY
and cannot be converted to natural gas.
furnace, open the furnace door and check the model number on the label
(see the table in the manufacturer' owner's manual). Use only the type of
gas your furnace has been set for. ONLY the 8900 AC-III series can be
converted by a qualified Service Technician to use either Propane (LP) or
Natural (NAT) gas.
DO NOT refuel gasoline tanks or LP tanks unless the gas has been turned
OFF AT THE LP TANK disabling all gas appliances and pilot lights.
DO NOT over fill LP gas tanks.
LP tanks must be filled by a qualified gas supplier only.
manufacturer's operating instructions located on the tank.
from an over filled tank can be forced through the pressure regulator
resulting in high pressure gas escaping, causing fire/explosion.
Turn gas OFF AT THE LP TANK when the vehicle is in motion.
disables all gas appliances and pilot lights.
DO NOT store or use gasoline or other flammable vapors and/or liquids in
the vicinity of this or any other appliance.
DO NOT use the furnace cabinet area as a storage compartment.
DO NOT block furnace outlet registers or return air grille.
Keep all insulating material away from furnace.
DO NOT alter the furnace to a positive grounding system.
DO NOT use battery charger to supply power to DC model furnace even
when testing.
I
WARNING:
DO NOT use 120-volt AC current with DC models.
Should overheating occur, or the gas supply fail to shut off, shut off the
manual gas valve to the furnace before shutting off the electrical supply.
DO NOT use furnace if any part has been under water. Immediately call a
qualified Service Technician to inspect the furnace and replace any part of
the control system and any gas control which has been under water.