EVERY THREE MONTHS OR 3,000 MILES
Vacuum around LP Burner and pilot light areas.
Compare water heater pilot flame with ideal flame. Refer to the water heater owner's manual
for ideal flame. Clean and adjust as necessary.
Compare refrigerator pilot flame with ideal flame. Refer to the refrigerator owner's manual for
ideal flame. Clean and adjust as necessary. (RV type refrigerator only)
Inspect refrigerator door seals.
Inspect refrigerator combustion seals. (RV type refrigerator only)
Check LP gas lines for leaks.
EVERY THREE MONTHS OR 3,000 MILES (CONTINUED)
Inspect LP cylinders for rust pits, gouges, scrapes or sharp dents. Repaint cylinders if rust is
present.
Drain and sanitize fresh water system.
Check, clean, tighten and lubricate battery cables.
EVERY FOUR MONTHS OR 4,000 MILES
Flush out water heater tanks.
EVERY SIX MONTHS OR 6,000 MILES
Clean drains with approved drain cleaners.
Check pipe connections for tightness. Tighten if necessary.
Lubricate all moving parts on the entrance steps.
Lubricate entrance and baggage door locks.
Inspect wheels for cracks, dents or distortion.
Inspect and reseal all sealant and putty tape.
Lubricate the elevating gear on the television antenna.
Lubricate the bearing surface between the rotating gear housing and the base plate on the
television antenna.
Lubricate the rubber quad ring on the elevating shaft located on the television antenna.
EVERY YEAR OR 12,000 MILES
Lubricate moving parts on the awning hardware. (Awning option only.)
Manually operate the pressure-temperature control lever or dial to the lowest possible position
on the water heater.
Clean city water entry strainer.
Check demand tank vent for obstructions.
Check water pump connections and mountings for tightness.
Vacuum the LP gas detector cover.
Rotate Fluorescent tubes in the light fixtures.
Clean absorption refrigerator flue. (RV type refrigerator only.)
Replace battery on the carbon monoxide detector. (Generator/Generator Prep option only.)
Have LP gas system inspected and serviced by a qualified technician.
Inspect and seal corners at the threshold of the entrance door.
Have the refrigerator inspected and serviced by a qualified technician.
Have furnace inspected and serviced by a qualified technician.
EVERY SIX YEARS
Replace carbon monoxide detector (Generator/Generator Prep option only.)