Installation and Rack Mounting

Two mounting solutions are available for installing the P300:
CRT1 19" Rack Tray (optional accessory): Supports up to 2 devices
(two P300s or one P300 and one ANI4IN, ANI4OUT, ANI22, or ANIUSB);
mountable in a rack or under a table
Single-unit Mounting Tray (included accessory): Supports a single de-
vice for mounting under a table
Securing the Devices
Use the included screws from the mounting hardware kit to secure each
P300 or Audio Network Interface (ANI). Devices can be mounted to face
either direction. Insert the screws from the bottom in the appropriate holes,
according to the following diagrams:
Align the holes as shown for securing a single device in the single-unit
mounting tray
Align the holes as shown for securing up to two devices in the 19" rack
tray.
Rack Ear Configuration (CRT1)
The adjustable rack ears support mounting in a standard equipment rack
or underneath a table.
Standard 19" Rack Mount
1. Align the ears with the mount-
ing holes pointed forward.
2. Install the 3 screws that hold
the ear to the tray as shown.
Under-table Mounting
1. Align the ears with the mount-
ing holes pointed upward.
2. Install the 3 screws that hold
the ear to the tray as shown.
Installing Underneath a Table
1. Hold the tray in the desired location under a table
2. Use a pencil to mark the location of the mounting holes on the table.
3. Drill 4 holes for the screws. The diameter of
the holes in the tray are 7.1 mm.
4. Install the components into the tray
5. Install with 4 screws to secure the tray underneath the table

Power Over Ethernet Plus (PoE+)

This device requires PoE Plus to operate. It is compatible with both Class
4 PoE+ sources.
Power over Ethernet is delivered in one of the following ways:
• A network switch that provides PoE+
• A PoE+ injector device (must be a Gigabit device)
Reset
The reset button is located inside a small hole in the rear panel. Use a pa-
perclip or other small tool to press the button.
There are two hardware reset functions:
Network reset (press button for 4-8 seconds)
Resets all Shure control and audio network IP settings to factory
defaults
Full factory reset (press button for longer than 8 seconds)
Restores all network and web application settings to the factory
defaults.
Software Reset Options
Reboot Device:In the web application (settings > factory reset), there is a
Reboot Device button, which simply power-cycles the device as if it were
unplugged from the network. All settings are retained when the device is
rebooted.
Restore Factory Defaults: In the web application (settings > factory re-
set), this restores all network and web application settings to the factory
defaults. This is the same as performing a full factory reset using the reset
button on the device.
Default Settings Preset: To revert audio settings back to the factory con-
figuration (excluding Device Name, IP Settings, and Passwords), select
Load Preset and choose the default settings preset.