Promax TV EXPLORER HD ISDB-T Manual page 160

Universal tv explorer
Table of Contents

Advertisement

Available languages

Available languages

In order to change the measurement mode press
screen like the following one:
Figure 23.- Analogue signal level measurement in terrestrial band.
Turn the rotary selector
[12] key to select the type of measurement to highlight on the monitor.
The available types of measurements are:
LEVEL:
C/N:
V/A:
FM Deviation:
When at the RF input appear an important number of carriers with a high level the tuning
circuit may become out of control, giving as a result wrong level measurements. To be
able to determinate the equivalent level of a carrier group (with similar levels) at the RF
input, it is possible to use the expression:
L t =L + 10 log N
L t : equivalent total level
L: average level of the carriers group
N: number of carriers
Page 50
USER'S MANUAL. TV EXPLORER
[1] to change the tuning channel/frequency. Press the
Level indication on the upper part of the screen (analogue
bar).
Carrier/Noise ratio measurement.
Video/Audio ratio measurement.
Measure the frequency peak deviation for any modulated
analogue carrier in FM.
HD
ISDB-T/T
[12] key, it will appear a
WARNING
11/2010
B

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Promax tv explorer hd isdb-tb

Table of Contents