DROPSA Dragon Series User Operating And Maintenance Manual

DROPSA Dragon Series User Operating And Maintenance Manual

Hide thumbs Also See for Dragon Series:

Advertisement

Quick Links

http://www.dropsa.com
Via Benedetto Croce, 1
Vimodrone, MILANO (IT)
t. +39 02 250791
DRAGON X PUMP
User Operating and
Maintenance Manual
Original instructions

TABLE OF CONTENTS

1.
2.
3.
4.
5.
6.
UNPACKING AND INSTALLING
7.
8.
9.
11. ORDERING INFORMATION
The manual has been prepared in compliance with Directive
CE 06/42
Dropsa products can be purchased from Dropsa branches and authorized distributors,
www.dropsa.com/contact or contact us sales@dropsa.com
C2150IE WK 20/20
visit

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Dragon Series and is the answer not in the manual?

Questions and answers

Summary of Contents for DROPSA Dragon Series

  • Page 1: Table Of Contents

    The manual has been prepared in compliance with Directive C2150IE WK 20/20 CE 06/42 http://www.dropsa.com Via Benedetto Croce, 1 Dropsa products can be purchased from Dropsa branches and authorized distributors, visit Vimodrone, MILANO (IT) www.dropsa.com/contact or contact us sales@dropsa.com t. +39 02 250791...
  • Page 2: Introduction

    70 bar (1015 psi). The latest version may be obtained from the Technical-Commercial Office, or by consulting our web site http://www.dropsa.com. The pump subject of this manual must be used by qualified personnel with basic hydraulic and electrical knowledge.
  • Page 3: Technical Characteristics

    < 70 dB(A) N.b. The specifications refer to the temperature of use of +20°C (+68°F) revolutions with load less motor * If a different product is used, please contact Dropsa S.p.A. to ensure it is suitable for use (see page 12)
  • Page 4 4.1 HYDRAULIC SYSTEM Fig. 1 Hydraulic diagram Fig.2 Hydraulic diagram with check valve The only connection to make is to connect the pump to the point to lubricate or to the metering valves.
  • Page 5: Components

    5. COMPONENTS PUMP COMPONENTS Motor Connector Pump Level indicator (optical in floating the picture – switch optional) Filter Tank Distributor block Non-return valve (optional) By-pass adjustment screw Clamping bracket Pressure switch (optional) Pressure gauge Plug 6. UNPACKING AND INSTALLATION 6.1 UNPACKING Once the suitable location for installation has been identified, open the package and remove the pump.
  • Page 6 V- (GND) Out N Out P 6.4 OPTICAL LEVEL CALIBRATION The level is tested and calibrated with oil by Dropsa, however is recommended before starting the pump to following the procedure below: Fill the reservoir; Open the front regulating hole;...
  • Page 7: Operating Instructions

     Use safety gloves or glasses as specified in the safety sheet for the lubricating oil  DO NOT use aggressive lubricants with NBR gaskets. In the case of doubt, contact the Dropsa SpA technical office to receive a detailed card about the recommended oils.
  • Page 8: Troubleshooting

    If you were not able to solve the problem after consulting the diagnostics table, do not try to find the fault by disassembling machine parts but contact the Dropsa technical office and report the anomalies that have been discovered, with a detailed description.
  • Page 9: Maintenance Procedure

    In the case of doubts and/or problems that cannot be solved, do not try to discover the reason by disassembling machine parts, but contact the DROPSA S.p.A technical office. 10. DISPOSAL During machine maintenance, or if it is demolished, do not dispose of the polluting parts in an improper manner. Refer to the local regulations for their correct disposal.
  • Page 10 11.2 SPARE PARTS PART NUMBER ITEM DESCRIPTION Flow rate *350 CC 3099186 PUMP Flow rate *500 CC 3099187 230-400 V 50 Hz three-phase- 0.09 KW 4P 3301544 265-460 V 60 Hz three-phase- 0.11 KW 4P 230 V 50 Hz single phase – 0.09 KW 4P 3301545 MOTOR 110 V 50 Hz single phase –...
  • Page 11: Dimensions

    12. DIMENSIONS CONTROL UNITS 3L pump 6L pump 3L 24V pump 6L 24V pump...
  • Page 12: Handling And Transportation

    13. HANDLING AND TRANSPORTATION Before shipping, the 39050.. pumps are carefully packed inside cardboard boxes. When transporting and storing the equipment, pay attention to the direction indicated on the boxes themselves. Upon receipt, check that the package has not been damaged and store the equipment in a dry location. Manual handling must be done by at least two people.
  • Page 13: Operating Hazards

    Fire – explosion – damage to the gaskets Corrosive products Pump corrosion - damage to people Water Pump oxidation Food substances They would be contaminated * For more detailed information regarding product compatibility with particular fluids, contact the Dropsa S.p.A. technical office...