The manual has been prepared in compliance with Directive C2150IE WK 20/20 CE 06/42 http://www.dropsa.com Via Benedetto Croce, 1 Dropsa products can be purchased from Dropsa branches and authorized distributors, visit Vimodrone, MILANO (IT) www.dropsa.com/contact or contact us sales@dropsa.com t. +39 02 250791...
70 bar (1015 psi). The latest version may be obtained from the Technical-Commercial Office, or by consulting our web site http://www.dropsa.com. The pump subject of this manual must be used by qualified personnel with basic hydraulic and electrical knowledge.
< 70 dB(A) N.b. The specifications refer to the temperature of use of +20°C (+68°F) revolutions with load less motor * If a different product is used, please contact Dropsa S.p.A. to ensure it is suitable for use (see page 12)
Page 4
4.1 HYDRAULIC SYSTEM Fig. 1 Hydraulic diagram Fig.2 Hydraulic diagram with check valve The only connection to make is to connect the pump to the point to lubricate or to the metering valves.
5. COMPONENTS PUMP COMPONENTS Motor Connector Pump Level indicator (optical in floating the picture – switch optional) Filter Tank Distributor block Non-return valve (optional) By-pass adjustment screw Clamping bracket Pressure switch (optional) Pressure gauge Plug 6. UNPACKING AND INSTALLATION 6.1 UNPACKING Once the suitable location for installation has been identified, open the package and remove the pump.
Page 6
V- (GND) Out N Out P 6.4 OPTICAL LEVEL CALIBRATION The level is tested and calibrated with oil by Dropsa, however is recommended before starting the pump to following the procedure below: Fill the reservoir; Open the front regulating hole;...
Use safety gloves or glasses as specified in the safety sheet for the lubricating oil DO NOT use aggressive lubricants with NBR gaskets. In the case of doubt, contact the Dropsa SpA technical office to receive a detailed card about the recommended oils.
If you were not able to solve the problem after consulting the diagnostics table, do not try to find the fault by disassembling machine parts but contact the Dropsa technical office and report the anomalies that have been discovered, with a detailed description.
In the case of doubts and/or problems that cannot be solved, do not try to discover the reason by disassembling machine parts, but contact the DROPSA S.p.A technical office. 10. DISPOSAL During machine maintenance, or if it is demolished, do not dispose of the polluting parts in an improper manner. Refer to the local regulations for their correct disposal.
Page 10
11.2 SPARE PARTS PART NUMBER ITEM DESCRIPTION Flow rate *350 CC 3099186 PUMP Flow rate *500 CC 3099187 230-400 V 50 Hz three-phase- 0.09 KW 4P 3301544 265-460 V 60 Hz three-phase- 0.11 KW 4P 230 V 50 Hz single phase – 0.09 KW 4P 3301545 MOTOR 110 V 50 Hz single phase –...
13. HANDLING AND TRANSPORTATION Before shipping, the 39050.. pumps are carefully packed inside cardboard boxes. When transporting and storing the equipment, pay attention to the direction indicated on the boxes themselves. Upon receipt, check that the package has not been damaged and store the equipment in a dry location. Manual handling must be done by at least two people.
Fire – explosion – damage to the gaskets Corrosive products Pump corrosion - damage to people Water Pump oxidation Food substances They would be contaminated * For more detailed information regarding product compatibility with particular fluids, contact the Dropsa S.p.A. technical office...
Need help?
Do you have a question about the Dragon Series and is the answer not in the manual?