ProPAC-3 Minimum Installation
1.Connector P4 (AC Power) is Pre-wired with 18" leads. This is the only connector with external leads
Shown with bold lines.
2.Input 1 * (Opto-22, AC solid isolated state Input Module) - used for Product Pulse Input
3.Output 1 ** (Opto-22, mechanical relay Output Module) - used for injector Load Permissive Output
4.The following connectors are pre-wired and connected to ProPAC-3 system components: P5 OFF/ON Switch, P3
Solenoid, P6 Heater, P11 Additive Flow Meter, and P1*** Test Injection Button.
* ProPAC-3 may be special ordered with a DC Input Module, DC 1:1 product pulses are highly recommended by Titan
Industries. Note: Shielded cable must be used if a DC input module is used. Input 1 module must match the input
voltage provided to the injector.
** ProPAC-3 may be special ordered with an AC or DC Output Module. Connector P2 pin 3 (-) and Pin 4 (+) are used
for Load Permissive output wiring. Please note polarity considerations.
Pro Pac-3 Main Circuit Board Wiring Schematic
Minimum Product (AC Pulse)
47
-12
GND
+5
GND
+12
provided.