9. Removal of Connecting Duct
Procedure
Step
1
Detach the humidifying
hose from the duct unit.
Remove the screw of
2
the duct unit.
Lift the right side to
3
unfasten the
projections and slide
the duct unit to the left.
Removal Procedure
Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Humidifying
hose
Projection
Move alternately.
(R13968)
(R5721)
Duct unit
(R18710)
Removal of Connecting Duct
Points
Preparation
Remove the front grille
according to "Removal of
Front Grille".
Since inside of the
humidifying hose has
ridges, move the hose up
and down to remove.
31